Emergency Stop - Bosch Rexroth IndraControl VAM 11.1 Project Planning Manual

Table of Contents

Advertisement

DOK-SUPPL*-VAM*11/41**-PR03-EN-P
Rexroth IndraControl VAM 11.1/41.1 Machine Control Panels
4.4

EMERGENCY STOP

Tightening torques
AC voltage
Utilization category AC-15
DC voltage
Utilization category DC-13
Fig.4-9:
N/O contact ZBE 101 and N/C contact ZBE-102 according to DIN EN
60947-6-1, technical data
Manufacturer
Designation of the manufac‐
turer
Voltage range
Power consumption
Fig.4-10:
Technical data, LED module ZBV-B1
For further information, please refer to the data sheet of the manufacturer.
Manufacturer
Designation of the manu‐
facturer
Connection cross-section
Tightening torques
AC voltage:
Utilization category AC-15
DC voltage:
Utilization category DC-13
B10d value BS844 button
Bosch Rexroth AG
0.8 Nm (1.2 Nm max.)
240 V
120 V
250 V
125 V
Télémecanique (Schneider Electric)
LED module: ZBV-B1
AC (AC voltage)
DC (DC voltage)
Direct connection 24 V AC / DC
Télémecanique (Schneider
Electric)
EMERGENCY STOP but‐
ton, circumvention-proof,
rotary release: BS844
Standard auxiliary switch,
N/O contact: ZBE-101
Standard auxiliary switch,
NC contact (with forced
opening): ZBE-102
Fastening flange: BZ009
Minimum without core end
sleeves
Maximum without core end
sleeves
0.8 Nm (1.2 Nm max.)
240 V
120 V
250 V
125 V
Mechanics:
B10d = 600,000 (according
to the manufacturer)
Assumption: B10d = 2 x
B10
Exclusion of failure at <
6050 switching cycles
27/83
Technical Data
3 A
6 A
0.27 A
0.55 A
21.6 V – 26.4 V
19.2 V – 30 V
18 mA
Notes:
Standard auxiliary switch
N/O contact is not available
on all VAM variants
1 x 0.22 mm²
2 x 1.5 mm²
3 A
6 A
0.27 A
0.55 A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth indracontrol vam 41.1

Table of Contents