2.14 Control Circuit Wiring
2.14
Control Circuit Wiring
This section gives information about wiring the control circuit.
◆
Control Circuit Connection Diagram
Wire the drive control circuit as shown in
*1
To operate the control circuit while the main circuit power supply is OFF, connect a 24 V power supply unit
(option).
*2
Install a wire jumper between terminals SC-SP-SN to select the type of the power supply for MFDI (sinking/
sourcing mode or internal/external power supply).
NOTICE: Do not close the circuit between terminals SP and SN. Failure to obey will cause damage to the drive.
• Sinking Mode: Install a jumper between terminals SC and SP.
104
Figure
2.102.
Figure 2.102 Control Circuit Connection Diagram
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual