Cleaning The Combustion Chamber, Finned Grate And Flue Gas Collector Chamber - Viessmann Vitoligno 300-C Installation And Service Instructions For Contractors

Pellet boiler
Table of Contents

Advertisement

Commissioning, inspection, maintenance
Overview of maintenance and cleaning work on...
Activity
Check all gaskets on the covers and replace if nec-
essary.
Maintenance of moving parts (drive chains, cogs,
shafts and bearings)
Check all installed position switches.
Cleaning the combustion chamber, finned grate and flue gas collector
chamber
E
F
G
Fig. 34
1. Clean reversing chamber
and finned grate
B
C
vacuum cleaner.
2. Clean flue gas collector chamber
brush and vacuum cleaner.
3. Clean Lambda probe
ing with a soft brush. Inspect the Lambda probe for
damage.
44
A
, combustion chamber
A
with a cleaning brush and a
with a cleaning
D
E
on the inside of the hous-
After pellet consumption
of 4000 kg or at least an-
nually
X
X
4. Clean fan impeller
uum cleaner and inspect for damage.
5. Clean inside of cover and inspect gasket
damage.
6. Clean flue outlet
uum cleaner.
(cont.)
After pellet consumption of
10,000 kg or at least every
3 years
X
H
D
C
B
with a soft brush and a vac-
F
G
with a cleaning brush and vac-
H
for

Advertisement