Codes
Code 2
(cont.)
8.
to confirm.
d
"Adopted" appears briefly in the display.
9.
Exit the service menu.
ä
Overview
The coding addresses are displayed in groups, subject
to system configuration:

"General"

See page 62

"Charging"

See page 62
General
Coding
Coding in the delivered condition
Fault message output delay
80:6
Minimum fault duration of 30 s be-
fore a fault message is issued.
Automatic summer/wintertime changeover
81:1
Automatic summer/wintertime
changeover
Outside temperature time constant
90:128
Time constant for calculating the
adjusted outside temperature
21.5 h
Outside temperature offset
92:0
No outside temperature correction. 92:- 10
Charging
Is available, if code "Charging scheme", Hardware
group, is selected.
Coding
Coding in the delivered condition
Charge time, combustion chamber
1E:130
Feed screw conveyor runtime of
130 s
Charge time, screw conveyor
1F:80
Feed screw conveyor runtime of
80 s to fill the feed screw conveyor.
62
"Heating"
See page 63
"Boiler"
See page 64
"DHW"
See page 67
Possible change
Adjustable from 0 to 995 s. 1 step ≙
80:0
to
5 s.
80:199
81:0
Manual summer/wintertime change-
over
90:0
Fast (low values) or slow (high val-
to
ues) matching of the flow tempera-
90:199
ture, subject to the set value accord-
ing to changes in outside tempera-
ture; 1 step ≙ 10 min
Correction of the outside tempera-
to
ture by the value set in °C.
92:10
Possible change
1E:10
Setting range in s
to
1E:240
1F:5
Setting range in s
to
1F:900