Recommended Shutdown Procedure

Figure 4-2
1 OFFLINE/RESET switch
Recommended Shutdown Procedure
Before pulling a DFE module out of a chassis, 
press or tap on its OFFLINE/RESET switch for less than 1 second. 
Its CPU LED changes from solid green to blinking between green and amber, indicating that the 
DFE module is shutting down. At the end of the DFE module shutdown routine, the CPU LED 
changes to a 67%/33% sequence of amber/off, respectively, indicating the module is in a halt state. 
In this time it is safe to restart or remove the DFE module from the chassis.
When a controlled shutdown is initiated from the OFFLINE/RESET switch, you have 60 seconds 
from the time the CPU starts flashing amber/off until the time the device is automatically 
restarted.
4-6 Troubleshooting
OFFLINE/RESET Switch
Caution: Do not pull any DFE-Diamond module out of an operating chassis before it has completed
its shutdown routine.
Precaución: No retire los módulos DFE-Diamond del chasis en funcionamiento hasta que no se
haya terminado con la rutina de apagado.
Note: The only safe time to pull a DFE module out of the chassis is when the CPU LED is blinking
amber. Otherwise, system operation will be interrupted.
7GR4280-19