Viessmann Vitoligno 300-H Installation And Service Instructions For Contractors page 93

Boiler for woodchips and pellets
Hide thumbs Also See for Vitoligno 300-H:
Table of Contents

Advertisement

Code 1
(cont.)
Coding in the delivered condition
Heating circuit 1
Heating circuit
No heating circuit 1 installed
1:No
Heating circuit 2
Heating circuit
No heating circuit 2 installed
2:No
Heating circuit 3
Heating circuit
No heating circuit 3 installed
3:No
Heating circuit 4
Heating circuit
No heating circuit 4 installed
4:No
Shut-off gate valve
Shut-off gate
No shut-off gate valve installed
v:No
Fuel store sensor
Silo sensor:No
No level sensor installed in the fuel
store
Solar
Solar:No
No solar group installed
Solar diverter valve
Solar diverter
The solar group connected to the
valve:No
boiler does not have a diverter
valve for charging the heating wa-
ter buffer cylinder.
Only available with code "Solar:On
the boiler" and if a heating water
buffer cylinder is installed.
Possible change
Heating circuit
Heating circuit is connected to the
1:On the boiler
boiler control unit.
Heating circuit
Heating circuit is connected to the
1:On the mixer
extension kit.
module
Heating circuit
Heating circuit is connected to the
2:On the boiler
boiler control unit.
Heating circuit
Heating circuit is connected to the
2:On the mixer
extension kit.
module
Heating circuit
Heating circuit is connected to the
3:On the boiler
boiler control unit.
Heating circuit
Heating circuit is connected to the
3:On the mixer
extension kit.
module
Heating circuit
Heating circuit is connected to the
4:On the boiler
boiler control unit.
Heating circuit
Heating circuit is connected to the
4:On the mixer
extension kit.
module
Shut-off gate
Shut-off gate valve installed
v:Yes
Silo sensor:Yes
Level sensor installed in the fuel
store
Solar:On the boil-
The solar group is connected to the
er
control unit of the boiler.
Solar:On the ex-
The solar group is connected to the
ternal solar mod-
external solar control unit.
ule
Solar diverter
The solar group connected to the
valve:Yes
boiler has a diverter valve for charg-
ing the heating water buffer cylinder.
Codes
93