GEM-DXRP1 / GEM-DXK1 Keypad Easy Program Menu
To create a custom program using the GEM-DXRP1 / GEM-DXK1 keypad, simply answer the following questions and record your informa-
tion on the Easy Menu Programming Worksheet. In each of the following steps, press
forwards, the PRIOR ("X" or
# o f Z n s i n A r e a 1
E n t e r # Z o n e s X X
(Direct Entry)
E Z Z o n e D o u b l i n g
E n a b l e d ?
Y / N
(Press YES or NO)
F i r e
Z o n e s
E n t e r Z o n e # ° °
(Direct Entry)
R e p o r t A l l Z o n e s
T o C e n t r a l ? Y / N
(Press YES or NO)
E x i t / E n t r y Z o n e s
E n t e r Z o n e #
(Direct Entry)
I n t e r i o r Z o n e s
E n t e r Z o n e #
(Direct Entry)
2 4 H o u r Z o n e s
E n t e r Z o n e #
(Direct Entry)
LIBRA LIB-P432EX Series Programming Instructions
u
q
) to go backwards,
Total Number of Zones in Area 1 (New Program Only)
Enter the total number of zones to be programmed for Area 1.
Valid entries are from 01 to 32. Directly enter the total number of zones, including leading zeros.
The system is based on groups of 4 zones each (after the first 8 zones), and will automati-
cally round up to the next group of 4. For example, if you enter 18, it will automatically con-
vert this to 20 zones. Press
Panel Zone Doubling (New Program Only)
To double the number of hardwired panel zones from 8 to 16, press
If Panel Zone doubling is not desired, press
The 16 zones will remain EOL terminated zones, requiring Normally Closed devices only.
Refer to Wiring Diagram and Installation Instructions for wiring instructions
Fire Zones in Area 1 (New Program Only)
Enter the zone number of any Fire Zones (including 2-wire, 4-wire or wireless).
Valid entries are from 01 to 32.
Directly enter each zone number, including leading zeros, and press
peat for any additional zone(s). Press
Local or Central Station Reporting System (New Program Only)
Press
p
for all zones to report; press
Exit/Entry Zones in Area 1 (New Program Only)
Enter the zone numbers of zones to be used as Exit/Entry zones.
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
X X
u
Press
to save and repeat for any additional zone(s); press
NOTE: Exit/Entry Entry time of 30 seconds will automatically be programmed.
Interior Zones in Area 1 (New Program Only)
Enter the zone numbers to be used as Interior Zones.
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
X X
u
Press
to save and then repeat for any additional zone(s).
Press
p
to proceed.
All Interior zones will also be automatically programmed as "Exit/Entry Follower" and as "Power
Up Delay" zones.
24 Hour Zones in Area 1 (New Program Only)
Enter the zone numbers of zones to be used as 24 Hour zones.
° °
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
u
Press
to save and repeat for any additional zone(s); press
NOTE: 24 Hour Zones will automatically be programmed as audible (Burg Output).
w
to save and
y
twice to exit at any time.
u
to save. Press
q
p
q
to set cursor, the NEXT ("r" or
p
to proceed.
p
.
u
to proceed.
for local system
p
to proceed.
p
to proceed.