System Delays & Timeouts - NAPCO Gemini GEM-P816 Programming Instructions Manual

Table of Contents

Advertisement

SYST EM DE LAY S & TIMEOU TS (ADDR ESS 0000-000 2, 1413, 1417, 2050 & 2055)
ADDRESS 0000
EXIT
ENTRY
DELAY
DELAY 1
(sec.)
[Default = 060]
Select delay/timeout (0-255 sec.).
EXIT/ENTRY DELAYS: Apply only to zones programmed with the following options "Exit/Entry 1, Exit/Entry
2, Exit/Entry Follower". For UL Installations, the maximum exit delay is 60 seconds and the maximum entry
delay is 45 seconds. NOTE: Sensor Watch Time Options are similar to above, except in hours.
U
Press
to save.
WARNING: Timers have uncertainty of +/-1 sec, so a "time" of 1 second may actually timeout IMMEDIATELY.
SYSTEM DE LAYS & TIM EOU TS (ADDRESS 1418-1419)
CHIME
ADDRESS 1418
TIME
(¼sec.)
[Default = 008
¼ sec. = 2 sec.]
x
1. Enter delay/timeout in corresponding address locations above.
Note: All entries for address 1418 are in quarter seconds (.25 seconds).
Therefore, the default of 008 results in a 2 second timeout.
U
2. Press
to save.
NAPCO Security Systems
R
ADDRESS 0001
ENTRY
DELAY 2
(sec.)
(sec.)
[Default = 030]
AC Fail
Report Delay
(min.)
ADDRESS 0002
PGM2 Output
Access Cntrl
Timeout (sec.)
[Default = 030]
[Default = 0 sec. = blank (•)]
ADDRESS 1419
[Default = 060]
ADDRESS 1413
ABORT
DELAY
(sec.)
Sensor Watch
Time
(Hrs.)
[Default = 024]
Report Cancel
Window
(min.)
[Default = 0 min. = blank (•)]
DEFAULTS: The defaults shown on this
page and on the following pages are
automatically set after exiting the Easy
Menu Driven Mode.
GEM-P816 Programming Instructions
Page 15
ADDRESS 1417
[Default = 030]
ADDRESS 2050
ADDRESS 2055