1. OPERATION
1.28

Alarms, Error Messages

1.28.1

Alarm indication

When the alarm is generated, the [ALARM] icon flashes (in red) and the audio alarm
sounds.
Icon indication
ALARM
ALARM
ALARM
How to acknowledge the alarm
Click the [ALARM ACK] icon to acknowledge the alarm and silence the audio alarm.
The [ALARM] icon continues flash until the cause of the alarm is cleared.
1-36
ROT
RIVER
RUDDER
1.2/ 0.5
SM
ALARM
HEAD-UP
HDG 123.4°
OFFCENT
OFF
L
STBY
Status
No alarm.
Red character and
An alarm is active.
flashing.
Red character and
All active alarms are acknowledged. Or all
not flashing.
alarms are not in alarm status but not
acknowledged.
[ALARM] icon
ALARM
ACK
[ALARM ACK] icon
(at the top left corner
on the screen)
Meaning