1. OPERATION
8. Click the center of the target B. The EBL bi-
sects target B.
9. Click the [VRM1] icon to change the
range. The [VRM1] icon turns yellow.
[VRM1] is linked to [EBL1]; [VRM2] is
linked to [EBL2].
10. Click the inner edge of the target B.
The VRM adjusts to put the VRM ring
on the target B. The point selected at
step 4 is the center of VRM.
11. Read the bearing at the [EBL] icon and the range at the [VRM] icon.
12. Do the same procedure for [EBL2] and [VRM2] to measure the range and bearing
between two other targets (target C and D), use EBL2 and VRM2 similarly.