Do not overtighten the waveguide mounting
screws. Overtightening may strip the threads in the
waveguide flange. Failure to comply could result in
equipment damage.
Überdrehen Sie die Hohlleiter-
Befestigungsschrauben nicht. Dadurch kann das
Gewinde im Hohlleiter-Flansch ausreißen.
Nichtbefolgen könnte Beschädigung des Gerätes
zur Folge haben.
6. Use a sequential tightening procedure Proceed as follows:
Partially tighten one of the screws (#1).
Move the tool to the screw that is diagonally opposite to
the screw tightened in step 1 (#2) and partially tighten that
screw.
Move clockwise to the next screw to be tightened (#3) and
partially tighten that screw.
Move to the screw diagonally opposite screw #3 and
partially tighten that screw (#4).
If required, repeat this process for the remaining screws
(#5-#6, #7-#8).
When you reach the first screw tightened in this step (#1)
increase the torque on the screw and repeat the process
until the screws have all been tightened to the correct
torque.
Figure 1, Typical 4 Screw Mounting Flange Tightening Sequence