Comtech EF Data XTRT-400C Operation And Installation Manual page 106

Table of Contents

Advertisement

Factory Settings
Factory use only.
Figure 39 – Cathode Current Optimization
Cathode Current Optimization
Cathode current optimization – TWT's with anodes can be configured such that the
cathode current is continually monitored and the anode voltage is adjusted periodically
to maintain the optimum cathode current. This in effect will extend the useful operating
life of the TWT by maintaining essentially the dame gain and output power levels that
were originally measured at the factory. This function is configured at the factory and
can be selected with the Enable.
Special Note: The cathode current optimization feature will automatically be disabled should
the measured cathode current fall out of a +/- 5% window from the original factory set point.
This will protect the TWT from excessive anode voltages should a failure occur in the
measurement circuit.
MNC-0400-071
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.
Page 46 of 53
Operation
Revision 4

Advertisement

Table of Contents
loading

Table of Contents