Bootup HV
This tab is used for setting high voltage state after a power cycle.
The options are:
1.
Restore Previous (High voltage comes back to same state as before power
interruption).
2.
High Voltage Always On (High Voltage will automatically come on following the
required filament time delay period).
3.
High Voltage Always Off (High voltage will always come back to the off state i.e.,
filament time delay then hold in standby mode).
Press and use knob to adjust.
Offset for RF Readings
This tab is used for entering an RF offset to the Forward power readings. This is
generally used to enter system gains or losses to be reported at the amplifier level. The
entered offset will be added or subtracted from the report RF power both on the LOCAL
monitor as well as via the remote RF power query. Press and use the knob to adjust.