Table 9, W/G Switch 1 Pinouts
Pin No.
12
Ground
13
+24 VDC
14
+15 VDC
15
-15 VDC
Wavequide switch 1 port is typically used for 1:1 redundant
systems. It provides switch control to the waveguide switch as
well as summary fault interface between the two amplifiers and
allows for configuring the system address required for Ethernet
configuration of the system. This interface is also used to
control switch 1 in 1+1 switch around systems. The pin-outs for
the connector can be found in Table 9 (above) of this chapter.
Table 10, W/G Switch 2 Pinouts
Pin No.
1
Position "A" command (+24 V active high)
2
Position "B" command (+24 V active high)
3
Command return (ground)
4
Position "A" indicator (active low)
5
Position "B" command (active low)
6
Indicator return (ground)
7
RF inhibit (normally closed to ground)
8
RF inhibit return (ground)
9
Summary fault 2 (input fault open)
10
Summary fault (output normally low)
11
Address select 2 (input low to select)
12
Ground
13
+24 VDC
14
+15 VDC
15
=15 VDC
Waveguide switch 2 port is typically used to control switch 2 in
1:2 redundant systems. It provides switch control to the
waveguide switch as well as summary fault interface between
the amplifiers and allows fo rconfiguring the system address
required for Ethernet configuration of the system. This interface
20 of 22