Description
The internal block upconverter can be bypassed for operation with
an input of 13.75 to 14.5 GHz..
For operation in this mode do the following:
To adjust the 10MHz reference signal to compensate for frequency
drift over time do the following:
MNC-0000-038
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.
Remove the loopback cable on the rear of the amplifier.
Terminate the upconverter O/P port with an SMA Male 50 ohm
termination Xicom Part Number 541-0001-002.
Terminate the IF input port with a Type N male 50 ohm termination
Xicom Part Number 541-0003-002.
Remove the dust cover screw labeled 10 MHz OSC ADJ.
With a small non-conductive adjustment screwdriver, adjust the
oscillator.
Replace the dust cover screw.