Verify Proper Fireplace Operation - Superior Fireplaces DRT4000-C Series Installation And Operation Instructions Manual

Direct-vent
Table of Contents

Advertisement

Innovative Hearth Products
DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces

Verify Proper Fireplace Operation

14.
1. With the gas line installed, inspect the system before closing the front of the unit.
2. Follow the pilot lighting instructions:
NOTE: When lighting the fireplace for the first time, it will take a few minutes for the gas line to purge itself of air.
When purged, the pilot and burner will light and operate as indicated. Subsequent lighting of the fireplace will not
require purging. Inspect the pilot flame (carefully remove logs, if necessary).
Electronic Fireplace Inspection
To light the burner, turn ON the wall or remote control switch. Ensure the igniter lights the pilot. The pilot flame
should engulf the thermocouple. Pilot should have two flames, one that engulfs the thermocouple and one that lights
the burner (see Figure 32).
Figure 32 - Electronic Pilot
Flame Rod