Superior Fireplaces DRT4000-C Series Installation And Operation Instructions Manual page 58

Direct-vent
Table of Contents

Advertisement

Innovative Hearth Products
DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces
Installing the Firebox Liners with Brackets
KIT CONTENTS
1 ea. Set of 4 Hand Bend Brackets
1 ea. Set of Optional Fiber Panels
1 ea. Installation Instructions
TOOLS / SUPPLIES NEEDED
Leather Gloves
GENERAL INFORMATION
FIELD SERVICE UPGRADES SHALL ONLY BE COMPLETED BY A QUALIFIED
SERVICE TECHNICIAN
The four (4) hand bend brackets are included to prevent movement of the
fiber firebox panels.
If you encounter any problems, need clarification of these instructions or
are not qualified to properly install this kit, contact you local distributor
or dealer.
Read this instruction sheet in its entirety before beginning the installation.
ALL WARNINGS AND PRECAUTIONS IN THE INSTALLATION AND OPERA-
TION MANUAL PROVIDED WITH THE APPLIANCE APPLY TO THESE
INSTRUCTIONS.
TURN OFF THE APPLIANCE AND ALLOW IT TO COMPLETELY COOL BEFORE
PROCEEDING.
Check the contents of the kits upon receipt and check for any damaged or
missing parts. If there is hidden damage, notify your freight company or
IHP dealer immediately.
INSTALLATION INSTRUCTIONS
1.
After removing Barrier and/or Facade and Glass Door per the fireplace
user manual instructions, install the rear fiber panel centered and flush
to the firebox rear panel (shorter bricks down) (see Figure 39A).
2.
Take Out the four brackets from the sheet metal set by bending the
sheet metal until the retaining tabs are broken free.
WATCH YOUR FINGERS! WEAR GLOVES!
58
Affected Fireplace Models
All
35" , 40" and 45" direct-
vent fireplace models offered with
Optional Fiber Panel Kits
CAUTION
SHARP EDGES - WATCH YOUR FIN-
GERS
Wear gloves to guard against any
sharp metal edges.
Figure 39A - Install Rear Fiber Panel
3.
Pre-bend a bracket and insert the top leg of the bracket between the
lintel and top panel as shown in Figure 39B.
4.
Install the side fiber panel by sliding it between the lintel and side panel
inserting the bottom rear edge first. Verify grout line alignment between
side and rear fiber panels.
CAUTION: Handle the fiber panels with care upon installation
to avoid cracks
5.
Hand bend the front top bracket by gently pushing the tab over the fiber
panel edge as shown in Figure 39C.
6.
Install the second fiber side panel by following instructions 3 to 7 bending
the brackets to the mirror direction shown on Figures 39B and 39C.
7.
Verify the alignment of the the side fiber panels with the rear panel and
install the glass door and barrier and/or facade following the instructions
in the fireplace User Manual.