Superior Fireplaces DRT4000-C Series Installation And Operation Instructions Manual page 39

Direct-vent
Table of Contents

Advertisement

Innovative Hearth Products
DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces
2. Install the outer Flex Pipe.
a. Install the large gear clamp loosely around the outer flexible vent pipe, then push it back out of the way.
b. Apply a bead of Mill-Pac Black (700 °F) high temperature sealant (P/N 10K81) to the outer adaptor collar.
c. Pull and extend the outer flexible vent.
d. Slide the outer flexible vent over the adaptor collar. Ensure the flexible vent completely engages the adaptor collar
e. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adaptor outer collar
f. Install three (3) sheet metal screws 120° apart through the flexible vent and into the adaptor collar just
3. Route the flexible vent.
NOTE: Ensure that the flexible vent is properly routed to provide the required clearance. Do NOT allow the flexible vent
to bend in a radius tighter than 5" (127 mm) (Figure 28). Place the internal flexible vent spacers evenly and avoid
kinking the inner vent. Support horizontal sections of flexible vent with metal straps at 2 ft (0.61 m) intervals.
4. Install firestop/spacers at ceiling and wall penetrations.
NOTE: See the appropriate sections and figures shown throughout the venting section for installation
requirements.
5. Attach the flexible vent to the termination.
NOTE: Secure Flex
flexible vent cut to size at the job site. Attach the flexible vent to the Secure Flex terminations as it was attached
to the adaptor (Figure 27).
NOTE: Attach Secure Flex vent to Secure Flex terminations only. Do NOT substitute Secure Vent
or Secure Vent adaptor for Secure Flex components. Secure Flex termination and adaptor collars are a
different circumference than Secure Vent collars. Secure Flex vent has an longer center tube to improve
ease-of-installation.
Cover to the grooves of the collar that extend approximately 1" from the end and to the flat surface,
approximately 1 3/8" from the end.
1-3/4" from the end, and that it is free from damage or tears.
approximately 3/4" from the end of the flexible vent.
below the gear clamp to provide additional security to the connection.
SF4.5VF firestop/spacer for ceilings
SF4.5HF firestop/spacer for walls
components can be purchased separately and attached to bulk lengths of Secure Flex
®
Installation
901032-00B, 07/2020
terminations
®
39