Complete The Field Wiring - Superior Fireplaces DRT4000-C Series Installation And Operation Instructions Manual

Direct-vent
Table of Contents

Advertisement

Innovative Hearth Products
DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces

Complete the Field Wiring

12.
The ground supply lead must be connected to the wire attached to the green ground screw located on the
outlet box (see wiring diagrams). Failure to do so will result in a potential safety hazard. The appliance
must be electrically grounded in accordance with local codes or, in the absence of local codes, the National
Electrical Code, ANSI/NFPA 70—latest edition (in Canada, the current CSA C22.1 Canadian Electrical Code).
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation.
Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de
cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
Electronic models of these appliances are equipped with a three-prong (grounding) plug utilized in
connecting the electronic components to the junction box in the lower compartment. This grounding plug
provides protection against shock hazard and should be plugged directly into a properly grounded three-
prong receptacle. DO NOT cut or remove the grounding prong from the plug.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adéquatement une fois l'entretien terminé.
The gas valve is set in place and pre-wired at the factory.
Figure 29 - Wiring Diagram—Junction Box
Green
White
Tab
Intact
Hot Side of
Receptacle
Green
Neutral
Ground
Side of
Screw
Receptacle
40
Ground - Green
Neutral - White
120 VAC - Black
Black
(Power
Junction Box
Supply
Unswitched)
Red
J-BOX / RECEPTACLE
Tab Intact
WIRING 120V, 60HZ, 1PH
Field Wired
Factory Wired
CAUTION
CAUTION
ATTENTION
WARNING
Installation
901032-00B, 07/2020