P/N 901032-00 REV. B 07/2020
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 901032-03.
P901032-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
DRT4000-C & DRT4200-C Series Direct-Vent Gas
Fireplaces
Models
C
US
DRT4040DEN-C
DRT4040DEP-C
Report No. 16-120
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
DRT4045DEN-C
DRT4045DEP-C
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
DRT4240DEN-C
DRT4245TEN-C
DRT4240DEP-C
DRT4245TEP-C

Advertisement

Table of Contents
loading

Summary of Contents for Superior Fireplaces DRT4000-C Series

  • Page 1 Installation and Operation Instructions DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces P/N 901032-00 REV. B 07/2020 Models Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 901032-03. DRT4040DEN-C DRT4240DEN-C DRT4045DEN-C DRT4245TEN-C DRT4040DEP-C DRT4045DEP-C DRT4240DEP-C DRT4245TEP-C Report No.
  • Page 2: General Information

    Innovative Hearth Products General Information DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 SAFETY AND YOUR FIREPLACE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
  • Page 3 Innovative Hearth Products General Information DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fireplace get chimenea IHP se ponen foyer IHP deviennent...
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de tion importante seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1.
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
  • Page 7 Innovative Hearth Products General Information DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 APPLIANCE OPERATION NOTICES These fireplaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Packaging List

    Innovative Hearth Products General Information DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 INSTALLATION PACKAGING LIST All models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (envelope in bottom compartment containing Installation and Operation Instructions (this manual), Hot Glass Safety Flyer, and Safety-In-Operation Warning Labels) •...
  • Page 9: Gas Pressure

    Innovative Hearth Products General Information DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 BTU Input Table 1 - Input Rate (BTU/HR), Gas Valves Natural Gas Propane Gas Models High Rate Low Rate High Rate Low Rate DRT4040-C 28,000 20,000 25,000 18,000 DRT4240-C...
  • Page 10 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
  • Page 11: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS These appliances are approved for installation in the US state of Massachusetts if the following additional requirements are met: • Install this appliance in accordance with Massachusetts Rules and Regulations 248 C.M.R. Sections 4.00 through 8.00.
  • Page 12: Manufactured Home Requirements

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 13: Vent Termination Clearances

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 14 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Table 7 - Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed...
  • Page 15: Minimum Clearances To Combustibles

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8), with the following exception: The unit may not be recessed (allowance made for mantel legs / side trim in Figure 5, Page 16). When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit (Figure 5).
  • Page 16: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Figure 5 - Combustible Side Clearances Figure 6 - Mantel Height At 6” (153 mm) At 6” minimum minimum side Mantel depth side wall clearance, wall clearance, a Top View of a combustible wall combustible wall...
  • Page 17: Installation Sequence

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions. Framing 1.
  • Page 18 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Table 10 - Fireplace Framing Specifications Model **NOTE: Dimension “D” is the Framing required framing depth when construction to be 40-7/8 41-1/4 43-3/4 28-1/4 10-1/2 units are installed with the DRT4240 Models 2 x 4, or larger.
  • Page 19: Prepare The Fireplace Top Spacers

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the fireplace cabinet are shipped flat. Remove the screw adjacent to the detached end (Figure 8A).
  • Page 20: Determine Vent Setup In The Combination Venting Unit

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Determining Vent Setup in the Combination Venting Unit Combination venting units are shipped with round outer flue covers and inner flue cover plates installed that will require removal before connecting the vent pipe. If you require a rear vented unit, remove the round outer rear flue cover (2 screws, Figure 10A) and the inner flue cover plate (4 screws, Figure 10B).
  • Page 21: Rough In The Electrical Supply, If Needed

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Rough in the Electrical Supply, if Needed As necessary, rough in the fireplace electrical supply per NEC and local codes. Place the Fireplace in the Framing and Secure NOTE: Nailing flanges, combustible members, and screw heads in areas directly adjacent to the nailing flanges are EXEMPT from the 1/2”...
  • Page 22: Vent System Preparation

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 VENT SYSTEM PREPARATION Select a Horizontal or Vertical Vent System 1. With the fireplace secured in the framing, determine the vent route and identify the exterior termination location. The following sections describe vertical (roof) and horizontal (exterior wall) vent applications.
  • Page 23: Install Vent Restrictor

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Figure 14B - Vent restrictor installation, Top vent Install the Vent Restrictor (if necessary) 1. Use the vent run descriptions in Figure 14A to determine if a vent restrictor is necessary. Installation in top vent.
  • Page 24 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Vent Restrictor with Vertical Terminations Figure 14D - Vent restrictor assembly When vertically terminating the vent system through the roof and using the vent restrictor, install the vent restrictor in the top vent of the fireplace outlet. If installing more than 6 ft of vertical venting, install the restrictor (Figure 14B), from Base inside or outside the unit, in the inner fireplace collar.
  • Page 25: Install Elbow Heat Shield, If Applicable (Required If Using A 90 Degree Elbow Directly Off Fireplace)

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Elbow Heat Shield If using a 90 degree elbow directly off fireplace (4040, 4240, 4045 SERIES MODELS ONLY), the elbow shield is required. Install per instructions in Figure 16. (4245 Series models require, at least, one foot of rise directly off unit before connection of elbow.
  • Page 26 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Vent section length table Table 14 will assist calculating how many vent sections are needed for the planned vent configuration. When a vent section is engaged with another section, its effective length will be 1-1/2” shorter. Table 14 - Vent Section Length Nominal Section Nominal Section Length...
  • Page 27: Install The Vent System

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.). For all vertical runs: • 1” (26 mm) from all sides NOTE: Attic insulation shield (H3907, see Page 51) must be installed when blown or loose-fill insulation is used, and is required for all attic installations.
  • Page 28 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Pages 24 and 26 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 29 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 7. Change vent direction of horizontal/inclined run—Install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. See Vent elbows on Page 24 for more information. 8.
  • Page 30 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Vertical Vent Figures/Tables NOTE: Secure Vent rigid vent pipe is shown in the figures; Secure Flex flexible vent pipe may also be used. ® ® NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4”...
  • Page 31 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 IMPORTANT NOTE: 4040, 4240, 4045 models may connect an elbow directly to the top flue collar. 4245 models must use, at a minimum, a 1 foot vertical section before connecting an elbow. Table 17 - Top Vent—Two 90°...
  • Page 32 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 33 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 8. Change vent direction—At transition from or to a horizontal/inclined run, install SV4.5E45 or SV4.5E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element.
  • Page 34 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Figure 25 - Installing the Horizontal Termination To help minimize water infiltration Firestop/Spacer (SV4.5HF) shown Typical it is recommended that the Fire- Termination on the exterior side of the wall. It Shown stop/ Spacer (SV4.5HF) be installed may also be installed on the...
  • Page 35 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Table 20 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9-1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 36 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Table 23 - Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum feet meters feet meters 1.524 0.305 When using Secure Flex, 3.048 0.610 use Firestop/Spacer SF4.5VF.
  • Page 37 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Table 26 - Rear Vent—Three 90° Elbows H + H Maximum H Maximum V Minimum feet meters feet meters feet meters Wall firestop/spacer Wall Firestop/Spacer SV4.5HF ** 1.524 0.610 0.305...
  • Page 38 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Vertical or Horizontal Venting Using Secure Flex Kits and Components ® When Secure Flex kits are used in a rear flue, horizontal termination installation, at least 1 ft of vertical rise is required. ®...
  • Page 39 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 2. Install the outer Flex Pipe. a. Install the large gear clamp loosely around the outer flexible vent pipe, then push it back out of the way. b.
  • Page 40: Complete The Field Wiring

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Complete the Field Wiring CAUTION The ground supply lead must be connected to the wire attached to the green ground screw located on the outlet box (see wiring diagrams). Failure to do so will result in a potential safety hazard. The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70—latest edition (in Canada, the current CSA C22.1 Canadian Electrical Code).
  • Page 41 8. After the wiring is complete, replace the cover plate. Figure 30A - Wiring Diagram—Electronic Gas Valve DRT4000-C series ELECTRONIC WIRING DIAGRAM FOR GRAVITY VENT FIREPLACES JUNCTION BOX...
  • Page 42 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Electronic Wiring DRT4200-C series One of the following optional controls must be used: • ON/OFF Control • Remote Control NOTE: Electronic models must be connected to the main power supply. 1.
  • Page 43: Connect The Gas Line

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Connect the Gas Line All codes require a shutoff valve mounted in the supply line. Figure 31 illustrates two methods for connecting the gas supply. The flex-line method is acceptable in the U.S., however, Canadian requirements vary depending on locality. Installation must be in compliance with local codes.
  • Page 44: Verify Proper Fireplace Operation

    1. With the gas line installed, inspect the system before closing the front of the unit. 2. Follow the pilot lighting instructions: • DRT4000-C series electronic systems Pages 69-70 • DRT4200-C series electronic systems Pages 71-72 NOTE: When lighting the fireplace for the first time, it will take a few minutes for the gas line to purge itself of air.
  • Page 45: Initialize Remote Control (Drt4200-C Series Only)

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 15. Initializing the Remote Control System (DRT4200-C models) 3. After completing fireplace installation, initialize the remote control system before operating the fireplace. Insert the three (3) provided AAA batteries into the battery bay in the transmitter, taking care to correctly align polarity ( + / - ).
  • Page 46: Install The Firebox Liners. (Required On Drt4200-C Models)

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Required Accessory: Install the Firebox Liners 1. See Page 58 for instructions: Installing the Firebox Liners. Install the Logs, Volcanic Stone, and Glowing Embers 1. See Pages 60–62 for instructions on Installing the logs, volcanic stone, and glowing embers. Install the Glass Door 1.
  • Page 47 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Figure 34A - FRONT Air Shutter Setting Figure 34B - REAR Air Shutter Setting Adjustment Rear Air Shutter Adjustment Lever Set-Screw Adjustment Rod Up Burner (Fully-Closed Tube Position) Air Shutter Closed...
  • Page 48: Install The Hood

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Install the Hood after fireplace is cool NOTE: All models must have a hood installed prior to operation. NOTE: Hood is slotted and has some adjustment. It is suggested that the center screw should be installed first and the ends last.
  • Page 49: Install The Finishing Materials

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Figure 35B - Lower Barrier Until it Seats into the Barrier Support Bracket. Spline Barrier Support Bracket Install the Finishing Materials 1. Complete finished interior wall. NOTE: To install the fireplace facing flush with the finished wall, position framework to accommodate the thickness of the finished wall.
  • Page 50 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 INSTALLER - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD...
  • Page 51: Installation Accessories

    Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 INSTALLATION ACCESSORIES IMPORTANT NOTE: The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual. Listed Secure Vent Components ®...
  • Page 52 Innovative Hearth Products Installation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 INSTALLATION ACCESSORIES (continued) Listed Secure Flex Components ® Cat. No. Model Description Cat. No. Model Description Vertical Termination for flex (flat 18 ft (5.49 m)* compressed flex 60L10 SF-18 to 6/12) with flex adaptor, section...
  • Page 53: Gas Conversion Kits

    Refer to the instructions provided with the conversion kit when performing any gas conversion. Install gas conversion kits per instruction provided in kits. DRT4000-C Series Electronic Systems, Natural Gas To Propane Gas Conversion Kits Electronic Systems, Propane Gas To Natural Gas Conversion (S.I.T.
  • Page 54: Operation

    Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 55 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD À LA SÉCURITÉ D’UTILISATION EN OPERACIÓN Your fireplace has been furnished with safety instruc- tion labels that are to be affixed to the operation and Votre foyer a été...
  • Page 56 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 57 With a battery backup, electronic fireplaces can automatically switch to battery power. In the event of a power outage, this allows ON/OFF operation (without blower functionality). Install new batteries before every burn season. DRT4000-C series 1. Open the control compartment door (Page 55), and locate the battery holder.
  • Page 58 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Installing the Firebox Liners with Brackets KIT CONTENTS Affected Fireplace Models 1 ea. Set of 4 Hand Bend Brackets 35" , 40" and 45" direct- 1 ea. Set of Optional Fiber Panels vent fireplace models offered with 1 ea.
  • Page 59 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Installing the Firebox Liners (continued) Example of Pre-Bent Bracket Before Insertion Bracket Insert Top Leg Of Bracket Between Lintel And Top Panel Figure 39C - Brackets Installed Figure 39B...
  • Page 60 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Install the Logs, Volcanic Stone, and Glowing Embers WARNING • Turn OFF all gas and electricity to the appliance before installing the volcanic stone, embers, and logs. •...
  • Page 61 DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Installing the DRT4200-C & DRT4000-C series 40” and 45” logs The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between flame peaks, so they do not impinge the flames.
  • Page 62 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 5. Place the middle left log #4 (Figure 47) on the setting pins in the middle of the grate (Figure 43). 6. Place the front left forked log #5 over log #4 as shown in Figure 48. One foot will rest between the 2nd and 3rd bar from the left on the grate.
  • Page 63 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 64 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located. Make sure the bead is not rolled into the channel at the top of the door, but remains flat against the top of the glass.
  • Page 65: Maintenance

    Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 MAINTENANCE Refer to the Maintenance Schedule on Page 67 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing. WARNING Turn OFF gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
  • Page 66 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated firmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 67 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure Inspecting/Cleaning Burner, Logs, and Qualified Service Technician Inspect valve and ensure it is properly...
  • Page 68: Accessory Components

    Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 ACCESSORY COMPONENTS Firebox Liner Kits Termination Guard Kits Firebox Media Termination Shroud (fits H1968) Blackstone Bag of Glowing Embers Bag of Platinum Embers Bag of Volcanic Stone Replacement ember materials or volcanic Blended Brown stone are available for use with these ap-...
  • Page 69 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 ACCESSORY COMPONENTS (cont.) DRT4000-C Series Only DRT4000-C Series Only Cost Effective Solution Unit-Mountable Rocker Switch Kit • Simple On/Off operation This rocker switch kit can be installed directly •...
  • Page 70: Lighting Instructions

    DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 LIGHTING INSTRUCTIONS, DRT4000-C SERIES - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 71 DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 LIGHTING INSTRUCTIONS, DRT4000-C SERIES - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 72 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 LIGHTING INSTRUCTIONS, DRT4200-C SERIES - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 73 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 LIGHTING INSTRUCTIONS, DRT4200-C SERIES - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 74: Troubleshooting

    Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 TROUBLESHOOTING - ELECTRONIC SYSTEMS Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 75: Replacement Parts

    Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 REPLACEMENT PARTS Cat. No. Model Description Cat. No. Model Description F4299 DRT4040DEN-C 40”, Elec, Black Int., NG F4305 DRT4240DEN-C 40”, Elec Top/Rear, NG F4300 DRT4040DEP-C 40”, Elec, Black Int., LP F4306 DRT4240DEP-C 40”, Elec Top/Rear, LP...
  • Page 76 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 REPLACEMENT PARTS (continued) 40” Models 45” Models Description Catalog Number Catalog Number Black touch-up paint, powder coat exterior F1882 F1882 Blower Assembly 80L84 80L84 Orifice Holder H7257 H7257 Gas Flex Line Connector 93L32...
  • Page 77 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 REPLACEMENT PARTS (continued) Electronic - DRT4000-C series Electronic - DRT4200-C series SIT Valve System Components DRT4040 DRT4045 DRT4240 DRT4245 Item # Description CAT No. CAT No. CAT No.
  • Page 78 Innovative Hearth Products Operation DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...
  • Page 79: Warranty

    Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials ®...
  • Page 80 Innovative Hearth Products Installation and Operation Instructions DRT4000-C & DRT4200-C Series Direct-Vent Gas Fireplaces 901032-00B, 07/2020 SuperiorFireplaces.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products (IHP) reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also...

Table of Contents