Complete The Field Wiring - Superior Fireplaces DRT Series Installation And Operation Instruction Manual

Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT/DRC3500 Series Direct-Vent Gas Fireplaces
f. Install three (3) screws 120° apart through the flexible vent and into the adaptor collar just below the gear
3. Route the flexible vent.
NOTE: Ensure that the flexible vent is properly routed to provide the required clearance. Do NOT allow the flexible vent
to bend in a radius tighter than 5" (127 mm) (Figure 29). Place the internal flexible vent spacers evenly and avoid
kinking the inner vent. Support horizontal sections of flexible vent with metal straps at 2 ft (0.61 m) intervals.
4. Install firestop/spacers at ceiling and wall penetrations.
NOTE: See the appropriate sections and Figures shown throughout the venting section for installation
requirements.
5. Attach the flexible vent to the termination.
NOTE: Secure Flex
flexible vent cut to size at the job site. Attach the flexible vent to the Secure Flex terminations as it was attached
to the adaptor (Figure 28).
NOTE: Attach Secure Flex vent to Secure Flex terminations only. Do NOT substitute Secure Vent
or Secure Vent adaptor for Secure Flex components. Secure Flex termination and adaptor collars are a
different circumference than Secure Vent collars. Secure Flex vent has an longer center tube to improve
ease-of-installation.

Complete the Field Wiring

12.
The ground supply lead must be connected to the wire attached to the green ground screw
located on the outlet box (see wiring diagrams). Failure to do so will result in a potential
safety hazard. The appliance must be electrically grounded in accordance with local codes
or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70—latest
edition (in Canada, the current CSA C22.1 Canadian Electrical Code).
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher.
Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adéquatement une fois l'entretien terminé.
The gas valve is set in place and pre-wired at the factory for both millivolt and electronic models.
Electronic Wiring
One of the following optional controls must be used:
ON/OFF Control
Remote Control.
See the Operation section on Page 50 for more details.
NOTE: Electronic models must be connected to the main power supply.
1. Route a 3-wire, 120 Vac, 60 Hz, 1 ph power supply to the fireplace junction box.
2. Remove the electrical inlet cover plate from the side of the unit by removing the plate's securing screws (Table 12).
3. If unit is not supplied with a strain relief, remove the cover plate knockout. Then, feed the power supply wire
through the knockout opening and into the unit junction box.
clamp to provide additional security to the connection.
SF4.5VF firestop/spacer for ceilings
SF4.5HF firestop/spacer for walls
components can be purchased separately and attached to bulk lengths of Secure Flex
®
CAUTION
CAUTION
ATTENTION
Installation
900298-00, 06/2018
terminations
®
37