\r\n
supportdevice=washer,heater\r\n
washer_status=off\r\n
PARAMETER
channel
supportdevice
washer_supportmode
washer_mode
washer_status
washer_dwelltime
heater_supportstatus
heater_status
VALUE
0~"capability_nvideoin"-1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
DESCRIPTION
Channel of the video source.
Get support peripheral device.
Get the support mode of washer control system,
its value is the same with "capability_peripheral_
c<0~(n-1)>_washer_mode".
*Only available when
capability_peripheral_c<0~(n-1)>_washer_supp
ort=1
Get the current mode of washer control system.
It return the value of "washer_mode"
* Available values are listed in
"capability_peripheral_c<0~(n-1)>_washer_mod
e"
Get the current status of washer control module.
The status is 'off' as default, which means the
washer is stopped; and the status 'on' means the
washer is running.
*Only available when
capability_peripheral_c<0~(n-1)>_washer_supp
ort=1
Get the current washer clean period of washer
control system.
*Only available when
capability_peripheral_c<0~(n-1)>_washer_supp
ort=1
Get the support status of heater control system.
*Only available when
capability_peripheral_c<0~(n-1)>_heater_suppo
rt=1
Get the current heater status.
Normally it will be 'auto', it means the heater
device is control by internal algorithm to keep in a
suitable environment; Otherwise is 'trigger', it
means the heater device is force enable to heat to
an internal condition.'trigger' status will be
VIVOTEK