Vivotek FD9165-HT User Manual page 30

Fixed dome network camera. 2mp 60fps, snv ii, wdr pro ii, remote focus, smart stream iii, 50m ir smart ir ii
Hide thumbs Also See for FD9165-HT:
Table of Contents

Advertisement

VIVOTEK
DI/DO Diagram
1. The DO+ pin provides a 5V output, and the max. load is 50mA.
2. The max. voltage for DO- pins is 30VDC (External power).
In order to control AC devices, the following diagram can be taken into consideration.
This diagram uses a relay to control the ON/OFF condition of the AC device.
3. An external relay can be triggered by using the DO+ or by an external power source,
depending on the type of relay you use.
4. In case of using an individual relay (instead of using a relay module), for protection
against voltage or current spikes, a transient voltage suppression diode must be
connected in parallel with the inductive load.
Dry contact with external DC power source to supply a relay. Dry contact is the safest connection
to protect devices.
PE
30 - User's Manual
DI-
DO+
DI+
Switch
DO-
Photo
Coupler
DC 0V
NO
External DC power
DC
DC 0V
NC
Relay
External Device
External AC power
with Protected Earth
AC
PE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fd9365-htvFd9365-ehtv

Table of Contents