Vivotek FD9165-HT User Manual page 165

Fixed dome network camera. 2mp 60fps, snv ii, wdr pro ii, remote focus, smart stream iii, 50m ir smart ir ii
Hide thumbs Also See for FD9165-HT:
Table of Contents

Advertisement

http://192.168.0.123/cgi-bin/admin/getparam.cgi?network_ipaddress
Response:
HTTP/1.0 200 OK\r\n
Content-Type: text/html\r\n
Context-Length: 33\r\n
\r\n
network.ipaddress=192.168.0.123\r\n
6. Set Server Parameter Values
Note: The access right depends on the URL directory.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/anonymous/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>...][&update=<value>][&return=<return page>]
http://<servername>/cgi-bin/viewer/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>...][&update=<value>] [&return=<return page>]
http://<servername>/cgi-bin/operator/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>...][&update=<value>] [&return=<return page>]
http://<servername>/cgi-bin/admin/setparam.cgi? <parameter>=<value>
[&<parameter>=<value>...][&update=<value>] [&return=<return page>]
PARAMETER
VALUE
<group>_<name>
value to assigned
update
<boolean>
return
<return page>
DESCRIPTION
Assign <value> to the parameter <group>_<name>.
Set to 1 to update all fields (no need to update parameter in each
group).
Redirect to the page <return page>after the parameter is assigned.
The <return page>can be a full URL path or relative path according to
the current path. If you omit this parameter, it will redirect to an
empty page.
(Note: The return page can be a general HTML file(.htm, .html) or a
VIVOTEK server script executable (.vspx) file. It cannot be a CGI
commandor have any extra parameters.This parameter must be
VIVOTEK
User's Manual - 165