Installation - Hussmann CSS13-2SV-1W Installation And Maintenance Instructions Manual

Combination service cabinet range
Table of Contents

Advertisement

CS Cabinet Range

Installation

Set Out When Installing Line-Up
Always identify the highest point on the floor where the cabinets are to be installed. Cabinets
will need to be levelled from this point.
Mark a line on the floor that shows the position of the rear skid rail for the line-up.
1.
Fit the foot bolt caps provided and position the first cabinet, level end to end and front to back.
2.
Ensure the foot bolts are adjusted (50mm nominal adjustment range) to accommodate the
highest point in the floor. All foot bolts must be adjusted to touch the floor. This will ensure
hinged glass maintains its position over time as the cabinet settles.
Apply a non-hardening, flexible sealant to the end of the cabinet to ensure a seal between the
3.
refrigerated area of the cabinet and the ambient environment.
It is advisable to apply masking tape to any visible joints to be sealed later, before butting up the
4.
adjacent cabinet.
Place the next cabinet as close as possible to first cabinet and set the height of the second
5.
cabinet to roughly match the first following the procedures in steps 3, 4, and 5.
Push the cases together and insert joining bolts. Make any minor adjustments to exactly align
6.
the two cabinets and tighten the joining bolts.
Check cabinet is level from end to end and front to back at both ends.
7.
Information in this manual is to be followed in conjunction with
specifications, work practices and regulations of the customer, installing
There is a 150 psig Dry Nitrogen (+/- 10psig) holding charge in the
evaporator coil, please check the pressure before safely releasing the
holding charge. If Dry Nitrogen holding charge is found to be below 140
psig, please undertake additional leak checks of the evaporator coil.
Cabinets shall be installed level front to back and side to side to allow
correct operation of lifting glass, and allow condensate to drain freely.
NOTE
company and relevant industry
CAUTION
NOTE
/ŶƐƚĂů ů ĂƟŽŶ D ĂŶƵĂů