1. Place the motor in a vise with the output shaft down.
Clamp across the mounting flange of the motor not the
housing. Excessive clamping pressure will cause distor-
tion. When clamping, use some protective device on the
vise, such as special soft jaws, pieces of hard rubber or
board.
Although not all drawings show the motor in a vise, we
recommend that you keep the motor in the vise during
disassembly and reassembly. Follow the clamping
procedures explained throughout the manual.
2. Remove 4 bolts from motor.
3. Lift valve housing straight up. If done carefully the
pins, springs, balance ring assembly, and valve will re-
main on the valve plate.
4. Carefully remove 3[76] diameter seal from valve
housing.
5. Remove case drain plug–with seal, from front valve
housing.