Meter (Gerotor) End Disassembly
1. Clamp unit in vise, meter end up. Clamp lightly on
edges of mounting area, see Fig. 25. Use protective ma-
terial on vise jaws. Housing distortion could result if jaws
are over–tightened.
2. Remove 5/16" cap screws.
3. Remove end cap.
4. Remove seal from end cap.
5. Remove meter. Be careful not to drop star.
6. Remove seal from meter.