3M 6000 Series Manual page 113

Full face mask
Hide thumbs Also See for 6000 Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 110
Make certain these markings are aligned for re-assembly.
Figure 11.
Neck Strap (7883). Connect loops at end of neck strap
assembly onto the face seal tabs at the top of the head
harness.
ACCESSORIES
Spectacle Kit (6878). Install rail assembly into Face Piece with
the plastic foot positioned on centre port adapter and the top
of rail is centered between the lugs or projections at top of
face seal. Install frame assembly onto rail assembly by
inserting pins into holes in rubber slide. Spectacles can now
be adjusted for optimal fit and vision.
Lens Covers (6885). Remove release liner from adhesive at
each side of replacement Lens Cover. Position lens cover over
the Face Piece Lens and adhere in place. Remove used lens
cover by lifting tab away from face piece.
CLEANING AND DISINFECTION
Cleaning is recommended after each use. If the respirator is to
be used for more than one shift it should be cleaned at the end
of each shift and stored between shifts in the original
packaging or a sealed container. To clean the respirator, the
3M™ 504 Wipe should be used to wipe the face seal of the
product. Remove the filters and disconnect the air supply unit
if appropriate. Clean parts (excluding filters) by immersing in
warm cleaning solution (water temperature not to exceed
50°C), scrub with soft brush until clean. Add neutral detergent
if necessary. Disinfect respirator by soaking in a solution of
quaternary ammonia disinfectant or sodium hypochlorite or
other disinfectant. Rinse in clean, warm water and air dry at
room temperature in a non-contaminated atmosphere.
CAUTION Do not use cleaners containing lanolin or other oils
on these products. Do not autoclave. Do not use petrol,
chlorinated degreasing fluids (such as trichloroethylene),
TECHNICAL SPECIFICATION
Respiratory Protection EN136 (Class 1) - for use with 3M Filters (bayonet) to EN14387:2004 or EN143:2000 and AS/NZS
1716:2012 (see Reference Leaflet).
3M6000 Series with ...
P1 Particulate Filters
P2 Particulate Filters
P3 Particulate Filters
Class 1 Gas & Vapour Filters
Class 2 Gas & Vapour Filters
3M™ Air Supply Unit
ES – Exposure Standard *AS/NZS 1715 Required Minimum Protection Factor
Eye Protection Meets the requirements of EN166 (Increased Robustness, Protection against High Speed Particles (medium
energy) and Lateral protection. Meets high impact rating and protection against hot solids to AS/NZS1337.
Flow Characteristics
Manufacturers Minimum Design flow (MMDF) 150 l/min.
Maximum Flow - See appropriate User Instructions.
Maximum Operating Temperature: +49 °C. CAUTION Care should be taken when using the equipment at low temperatures as
excessive moisture may cause the valves to freeze.
organic solvents or abrasive cleaning agents to clean any part
of the equipment. Do not reassemble parts until facepiece is
completely dry.
STORAGE AND TRANSPORTATION
These products should be stored in the packaging provided in
dry, clean conditions away from direct sunlight, sources of high
temperature, petrol and solvent vapours. The original
packaging is suitable for transporting the product. When
stored as stated, the expected shelf life of the product is 5
years from date of manufacture. Store in accordance with
manufacturer's instructions, see packaging.
]End of Shelf Life
\Temperature Range
,Maximum Relative Humidity
:Name and address of Manufacturer
J Dispose in accordance with local regulations
The date of manufacture can be established by examining the
date clock on the inside of the facepiece. Figure 12. The inner
segment will display the year, and the arrow will point to the
month of manufacture in the outer segment. The example
shows 01/09/2011 - 30/09/2011.
APPROVALS
These products are type approved and audited annually by
BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes
MK5 8PP, UK, Notified Body No. 0086. These products are CE
Marked to the requirements of Community Directive
89/686/EEC or European Regulation (EU) 2016/425. The
applicable legislation can be determined by reviewing the
Certificate and Declaration of Conformity at
www.3m.com/Respiratory/certs.
Maximum Exposure Limitations
10 x ES*
50 x ES*
Up to 100* x ES
Up to 50* x ES or 1000ppm (0.1% vol) whichever is lower.
Up to 100* x ES or 5000ppm (0.5% vol) whichever is lower.
100+ x ES
113