6.4. Tag Sets

The content of tag set settings to operate tag data links is shown below.
The data in the tag sets are assigned with the following OUT No. and IN No.
■Output area (Controller to Sensor Controller)
Originator variable (tag set name)
EIP050_OUT
OUT No.
Global variable name (tag name)
1
EIPOutput
■Input area (Sensor Controller to Controller)
Originator variable (tag set name)
EIP050_IN
IN No.
Global variable name (tag name)
1
EIPInput

6.5. Tag Data Link Table

The content of tag data link table settings (connection settings) is shown below.
The values marked with red squares are taken from the values defined in the EDS file for
Sensor Controller.
Connection Name
default_001
Connection I/O
Input /
Type
Output
Consume
Input
Data
From/Produce
Output
Data To
Precautions for Correct Use
The RPI and the timeout value are left as default values in this document.
When you set connections, change them according to your usage environment.
Connection I/O Type
Consume Data
From/Produce Data To
Target Variable
(Sensor
Size
Controller set
(Byte)
value: instance
number)
101
56
100
24
6.EtherNet/IP Settings
Data size (byte)
24
Data size (byte)
24
Data size (byte)
56
Data size (byte)
56
RPI (ms)
Timeout Value
50.0
RPI x 4
Originator Variable
(Tag set name)
EIP050_IN
EIP050_OUT
Size
Connection
(Byte)
Type
Multi-cast
56
connection
Point to
24
Point
connection
14