Connect The Hospitality Integrated Voice Services Card; To The Bgd Terminal - Nortel Communication Server 1000S Service Implementation Manual

Hospitality integrated voice services
Hide thumbs Also See for Communication Server 1000S:
Table of Contents

Advertisement

Connect the Hospitality Integrated Voice Services card

to the BGD terminal

Hospitality Integrated Voice Services uses the BGD terminal to make
requests to the system for AWU and DND services. To connect the BGD
terminal to the Hospitality Integrated Voice Services card and the system,
follow the steps in Procedure 12 on
Procedure 12
Connecting the BGD terminal
1
Position the terminal on a desk near the system.
2
Check the installation of the Ethernet adapter on the I/O panel (see
"Installing Ethernet adapter on Cabinet tip/ring connector" on page 57).
3
Check the installation of the NTBK48AA cable to the DB-9 male connector
on the Ethernet adapter.
4
Plug the terminal cable 25-pin female connector into the 25-pin male
connector (labeled Port 1) of the NTBK48AA cable (see Figure 6 on
page
terminal.
Note: A null modem is needed to make the connection for a DTE
connection (see Table 10 on
5
Plug the DB-9 or DB-25 male connector at the other end of the terminal
cable into the RS-232 connector on the terminal. (No null modem is
necessary).
If the connection requires a gender changer, obtain one at a local
electronics store. (See "Entering keycode information" on page 72 for
further information.)
Table 10
Connector pinout for the NT8K48AA (Part 1 of 2)
Adapter
Pin No.
3
2
5
Hospitality Integrated Voice Services Service Implementation Guide
Installation and configuration
60). Port 1 connects to the SDI that is configured as the BGD
Pin Name
RX RS-232 (CRT)
TX RS-232 (CRT)
GND RS-232 (CRT)
page
69:
page 69
for the connector pinout).
Pin Number
2
3
7
Page 69 of 136
Port Number
0
0
0