Installation and configuration
Configure the maintenance terminal
Enter the keycode information
553-3001-359 Standard 2.00 September 2004
Follow the steps in Procedure 14 to configure the maintenance terminal.
Procedure 14
Configuring the maintenance terminal
1
To access the CLI, use a VT100-type terminal.
Refer to "Connect the Hospitality Integrated Voice Services card
to the maintenance terminal" on page 62 for instructions on connecting
the VT100 terminal to the Hospitality Integrated Voice Services card.
2
Specify the VT100-type terminal interface characteristics to ensure
compatibility with the Hospitality Integrated Voice Services card interface.
3
Configure the interface parameters as follows:
•
Transmission speed: 9600 bps
•
Data bits: 8
•
Stop bit: 1
•
Parity: No
•
Flow control: none
Note: Do not use X-On/X-Off flow control.
When first connecting a VT100 terminal to the Hospitality Integrated Voice
Services card, the CLI appears and prompts to enter keycode information. To
enter the keycode information, follow the steps in Procedure 15:
Procedure 15
Entering keycode information
1
At the Modify, Save, Cancel: prompt, enter m to Modify.
2
At the max conf_ports (0): prompt, enter the number of ports that
corresponds to the Hospitality Integrated Voice Services card keycode
(for example., 8).
3
At the Modify, Save, Cancel: prompt, enter s to Save the modifications.
End of Procedure