Connecting To Two Power Sources; Connecting Power - Enterasys I Series Hardware Installation Manual

Industrial ethernet switch
Table of Contents

Advertisement

Do not connect power at this time.

Connecting to Two Power Sources

Refer to
Figure 2-17
To connect two power sources:
1.
Ground the I-Series chassis by attaching a 14 to 20 AWG solid copper ground cable
(customer-provided) to the ground connector on the front panel of the chassis directly below
the power connectors.
2.
Make sure the power supply is currently disconnected.
3.
Identify the positive and negative leads.
4.
Make sure the wires (14 to 20 AWG solid copper, customer-provided) are stripped to 0.25 inch
(6.3 mm) + 0.02 inch (0.5 mm). Stripping more can leave exposed wire from the power
connector.
5.
Insert the positive wire from the primary source into the primary connector (marked +), as
shown in
Figure 2-17
6.
Insert the negative wire from the primary source into the primary connector (marked -), as
shown in
7.
Insert the positive wire from the secondary source into the secondary connector (marked +), as
shown in
8.
Insert the negative wire from the secondary source into the secondary connector (marked -), as
shown in
Do not connect power at this time.
as you perform the following procedure.
Figure
2-17. Turn the screw to secure the wire.

Connecting Power

Figure
2-17. Turn the screw to secure the wire.
Figure
2-17. Turn the screw to secure the wire.
Figure
2-17. Turn the screw to secure the wire.
Connecting Power to the Switch
Enterasys I-Series Hardware Installation Guide 2-21

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

I3h252

Table of Contents