Electric Heat Kit Testing; Quick Start Guide For Non-Communicating Outdoor Units - Goodman MBVC 1 Series Installation Instructions Manual

Blower cabinet
Table of Contents

Advertisement

3. The 7 Segment display should not be displaying anything
at this point
4. Press and hold the RECALL button for 5 seconds. The 7
Segment display should show .. Release the RECALL
button.
5. Press and hold the RECALL button again for another 5
seconds. The 7 Segment display should show .. Release
the RECALL button.
6. Press and hold BOTH the RECALL AND TEST buttons for 5
seconds. the 7 Segment display should show .. Release
the RECALL AND TEST buttons. Note, if you only hold the
RECALL button during the step the display will show ..
You will then need to press the LEARN button and then start
over from step 5.
7. Press and release the RECALL button (do not hold it down)
until the 7 Segment display shows ..
8. Press and release the TEST button. the 7 Segment display
will show ..
9. Press and release the RECALL button. the 7 Segment display
will show .. Note: The display will be flashing at this
time.
10. Press and release the TEST button to stop the flashing
11. Press and release the TEST button againt
12. Step 12 successfully enabled charge mode. Press the
LEARN button to return to the main screen. The 7 Segment
display will be blank again. The Outdoor Inverter will start
up momentarily in charge mode and will remain in charge
mode for 1 hour.
NOTE: the installer must manually shut off charge mode once
complete. To do so, follow the same push button procedures as
shown above (steps 2-7). After pressing the RECALL button at step
8, if the 7 Segment display shows . it means the system has
already terminated charge mode. Pressing the LEARN button will
exit the menus. If after pressing the RECALL button at step 8, the
7 Segment displays still show ., press RECALL to change the
display to . then press the TEST button two times and finally
the LEARN button to exit the menus. The system will shut down
after a couple of minutes meaning charge mode is off.
Charging Instructions for a Two-Stage Outdoor Unit
1. Two-stage outdoor units using the CoolCloud HVAC
application:
a. Using the cooling icon after entering the outdoor
unit menus, energize the outdoor unit to 49%
capacity or lower.
Quick Start Guide for Non-Communicating
Outdoor Units
When setting up a ComfortBridge air handler for use with a
Non-Communicating outdoor unit you must set airflow in the "ton"
menu on the PCB or in the CoolCloud HVAC APP. Failure to do so
will result in the air handler PCB displaying "IdL" and the blower
will not operate with a call for cooling. The Board does not need
to be replaced, you MUST set the airflow first.
EXTREMELY IMPORTANT: For two stage electric heat kit control
the system only needs a single W input. Internal algorithms will
control staging automatically based on the single W input. For
non-communicating outdoor unit wiring, see instructions below:
1. Use the wiring diagrams on the next page to connect low
NOTE: When installing the air handler with a non-communicating
heat pump, wire directly to the "O" terminal on the non-commu-
nicating heat pump. See the following figures.
to
exit this menu
8
b. Charge the outdoor unit as required using the
charging information provided with the outdoor
equipment.
voltage thermostat wires.
Non-Communicating Single Stage A/C
Figure 10