ACNF, ADPF, AEPF, ARPF, ARUF,
ASPF, ATUF, AWUF Air Handlers
Refer to Service Manual RS6100004 & RS6200006 for installation, operation & troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman
does not assume any responsibility for property damage or personal injury due to improper
service procedures or services performed by an unqualified person.
Copyright ©
2007-2012
Goodman Company, L.P.
AL
AL
AL
AL
RT6121000r19
November 2012

Advertisement

loading

Summary of Contents for Goodman ARPF

  • Page 1 Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman RT6121000r19 does not assume any responsibility for property damage or personal injury due to improper November 2012 service procedures or services performed by an unqualified person.
  • Page 2: Product Identification

    Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Installation and repair of this unit Goodman will not be responsible WARNING WARNING WARNING...
  • Page 3 WARNING that is not design certified by damage, personal injury, or death, Goodman for use with this unit. do not store combustible materials or use gasoline or Serious property damage, personal injury, reduced unit other flammable liquids or vapors in the vicinity of this performance and/or hazardous conditions may result appliance.
  • Page 4: Product Design

    WARNING ARUF, ATUF AEPF / ASPF Insulation Kit If this appliance is installed in an enclosed area or ARPF Model such as a garage or utility room with any carbon 1729 DPI18-30/20 monoxide (CO) producing appliance (i.e. automo- 1824 bile, furnace, water-heaters, etc.), ensure the area...
  • Page 5 PRODUCT DESIGN To prevent the horizontal drain pan from sweating in high *ARPF air handlers are multi-position, multi-speed with di- humidity applications, it is recommended that a DPIH rect drive motors. They are available in 1 1/2 to 5 ton sizes insulation accessory kit be used.
  • Page 6: Product Dimensions

    PRODUCT DIMENSIONS ACNF IMENSIONS Model ACNF18 37¼” 34 ” 30” 6½” ” 36” 6½” ACNF24 43¼” 40 ACNF30 49¼” 46 ” 42” 6½” AC18 37¼” 34 ” 30” 6½” ” 36” 6½” AC30 43¼” 40 AC36 49¼” 46 ” 42” 6½”...
  • Page 7: Product Specifications

    PRODUCT SPECIFICATIONS ACNF ACNF*****AA/AB (copper coils) Blower Diameter 5.75 5.75 5.75 5.75 6.31 6.31 6.31 6.31 6.31 6.75 6.75 6.75 6.75 6.75 W idth 6.75 6.75 6.75 6.75 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 8.25 Coil Drain Connection FPT 3/4"...
  • Page 8: Blower Performance Data

    BLOWER PERFORMANCE DATA ACNF CFM delivered against External Static Pressure Model Speed 0.1” 0.2” 0.3” 0.4” 0.5” High ACNF18001 High ACNF18051 High ACNF18061 High ACNF18081 High ACNF24001 High ACNF24051 High ACNF24061 High ACNF24081 High ACNF24101 High 1,075 1,015 ACNF30001 High 1,075 1,015 ACNF30051 High...
  • Page 9 ACNF BLOWER PERFORMANCE DATA ACNF*****DA (with aluminum coils) CFM deliverd against External Static Pressure Model Speed 0.1" 0.2" 0.3" 0.4" 0.5" High ACNF180016 High ACNF180516 High ACNF180616 High ACNF180616 High ACNF240016 High ACNF240516 High ACNF240616 High ACNF240816 High ACNF241016 High 1,060 ACNF300016 High...
  • Page 10 PRODUCT DIMENSIONS ADPF ” Model ADPF18241/16 42 ” 22” 13½” 15½” 10” 3½” ” 13 ” 17 ” 15½” ” ADPF30421/16 53¼” 24” 20” 22” 12” 9¼” ” 19 ” 19 ” 21 ” 21¼” ADPF48601/16 53¼” 24” 20” 22” 12”...
  • Page 11 PRODUCT SPECIFICATIONS ADPF ADPF1824 ADPF3042 ADPF4860 1/16 1/16 1/16 Blower Diameter 9 1/2" 10 5/8" 10 5/8" W idth 6" 8" 10 5/8" Coil Drain Connection FPT 3/4" 3/4" 3/4" Lineset Connection Size Liquid 3/8" 3/8" 3/8" Suction 3/4" 7/8" 7/8"...
  • Page 12 PRODUCT DIMENSIONS AEPF ” [7.30 cm] Model AEPF18301/16 46 3/4" 22" 17 1/2" 19 1/2" 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" AEPF30361/16 53 1/4" 24" 20" 22" 12" 19 5/8" 11 15/16" 19 5/8" 19 15/16" 1 13/16" 53 1/4"...
  • Page 13 PRODUCT SPECIFICATIONS AEPF AEPF183016* AEPF303616* AEPF313716* AEPF426016* Blower Diameter 9 1/2" 10 5/8" 10 5/8" 10 5/8" Width 8" 10 5/8" 10 5/8" 10 5/8" Coil Drain Connection FPT 3/4" 3/4" 3/4" 3/4" Lineset Connection Size Liquid 3/8" 3/8" 3/8" 3/8"...
  • Page 14 BLOWER PERFORMANCE DATA AEPF The AEPF air handler blower motor is pre-programmed for operation at four distinct airflow levels when operating in the Cooling, Heat Pump heating, Backup heating (Electric Heating), and Backup + Heat Pump heating modes. Each modes has four levels to deliver different CFM. Simply flip the dipswitch for a different CFM combination. Setting the Motor Dipswitch Function...
  • Page 15 PRODUCT DIMENSIONS ARPF SUCTION LINE LIQUID LINE INLET TUBE INLET (RIGHT SIDE VIEW) INLET (FRONT VIEW) Model ARPF18241* 42 1/8" 22" 13 1/2" 15 1/2" 10" 14 1/2" 11 15/16" 13 1/8" 17 15/16" 2" ARPF19311* 46 3/4" 22" 17 1/2"...
  • Page 16 PRODUCT SPECIFICATIONS ARPF ARPF18241* ARPF19311* ARPF30301* ARPF36361* Blower Diameter 9 1/ 2" 9 1/ 2" 9 1/ 2" 9 1/ 2" Width 6" 6" 8" 6" Coil Drain Connection FPT 3/ 4" 3/ 4" 3/ 4" 3/ 4" Lineset Connection Size Liquid 3/ 8"...
  • Page 17 BLOWER PERFORMANCE DATA ARPF CFM deliverd against External Static Pressure M odel Speed 0.1" 0.2" 0.3" 0.4" 0.5" High 1155 1090 1025 ARPF18241* M ed. High 1135 1085 1025 ARPF19311* M ed. High 1385 1315 1240 1155 1065 ARPF30301* M ed.
  • Page 18 PRODUCT DIMENSIONS ARUF ” [7.30 cm] Model ARUF172916 42 1/8" 22" 13 1/2" 15 1/2" 10" 14 1/2" 11 15/16" 13 1/8" 17 15/16" 2" ARUF182416 42 1/8" 22" 13 1/2" 15 1/2" 10" 14 1/2" 11 15/16" 13 1/8" 17 15/16"...
  • Page 19 ARUF PRODUCT SPECIFICATIONS ARUF172916 ARUF182416 ARUF193116 ARUF303016 Blower Diameter 9 1/ 2" 9 1/ 2" 9 1/ 2" 9 1/ 2" Width 6" 6" 6" 8" Coil Drain Connection FPT 3/ 4" 3/ 4" 3/ 4" 3/ 4" Lineset Connection Size Liquid 3/ 8"...
  • Page 20 BLOWER PERFORMANCE DATA ARUF CFM deliverd against External Static Pressure M odel Speed 0.1" 0.2" 0.3" 0.4" 0.5" High 1155 1090 1025 ARUF172916 M ed. High 1155 1090 1025 ARUF182416 M ed. High 1135 1085 1025 ARUF193116 M ed. High 1385 1315 1240...
  • Page 21 PRODUCT DIMENSIONS ASPF ” [7.30 cm] Model ASPF183016* 46 3/4" 22" 17 1/2" 19 1/2" 14 1/2" 11 15/16" 17 1/8" 17 15/16" 2" 53 1/4" 24" 20" 22" 12" 19 5/8" 11 15/16" 19 5/8" 19 15/16" 1 13/16" ASPF303616* ASPF313716* 53 1/4"...
  • Page 22 PRODUCT SPECIFICATIONS ASPF AS PF183016* ASPF303616* AS PF313716* ASPF426016* B lowe r D iam eter 9 1/2" 10 5/8" 10 5/8" 10 15/16" W idth 8" 10 5/8" 10 5/8" 10 11/16" C oil D rain C onnec tion FPT 3/4"...
  • Page 23 BLOWER PERFORMANCE DATA ASPF CFM deliverd against External Static Pressure M otor M odel Speed Tap 0.1" 0.2" 0.3" 0.4" 0.5" ASPF183016 1075 1055 1015 1130 1115 1085 1040 1000 1060 1105 ASPF303616 1165 1070 1020 1285 1240 1195 1140 1100 1435 1395...
  • Page 24 PRODUCT DIMENSIONS ATUF ” [7.30 cm] Model ATUF182416 42 1/8" 22" 13 1/2" 15 1/2" 10" 14 1/2" 11 15/16" 13 1/8" 17 15/16" 2" ATUF193116 46 3/4" 22" 17 1/2" 19 1/2" 10" 14 1/2" 11 15/16" 17 1/8" 17 15/16"...
  • Page 25 ATUF PRODUCT SPECIFICATIONS ATUF182416 ATUF193116 ATUF303016 ATUF363616 Blower Diameter 9 1/2" 9 1/2" 9 1/2" 9 1/2" Width 6" 6" 8" 6" Coil Drain Connection FPT 3/4" 3/4" 3/4" 3/4" Lineset Connection Size Liquid 3/8" 3/8" 3/8" 3/8" Suction 7/8" 3/4"...
  • Page 26 BLOWER PERFORMANCE DATA ATUF CFM deliverd against External Static Pressure Model Speed 0.1" 0.2" 0.3" 0.4" 0.5" High 1,155 1,090 1,025 ATUF182416 Med. High 1,135 1,085 1,025 ATUF193116 Med. High 1,455 1,385 1,330 1,205 1,090 ATUF303016 Med. 1,340 1,290 1,230 1,140 1,050 1,075...
  • Page 27 AWUF PRODUCT DIMENSIONS Small Chassis Large Chassis AWUF 18 & 24 AWUF 30 & 36 36" 36" 20 3/8" 24" 16 1/8" 21" 16" 19 7/8" 11" 15 7/8" FILTER 14" X 18" X 1" FILTER 16" X 20" X 1" Large Chassis AWUF 31,32 &...
  • Page 28 PRODUCT SPECIFICATIONS AWUF[18-37]A* Heating Capacity Actual kW @ 240 volts BTU/h @ 240 volts 10,240 16,390 24,925 10,240 16,390 24,925 33,460 10,240 16,390 24,925 33,460 Blower Diameter 9" 9" 9" 10" 10" 10" 10" 9" 9" 9" 9" Width 6" 6"...
  • Page 29 PRODUCT SPECIFICATIONS AWUF[18-24]**16B* Heating Capacity Actual kW @ 240 volts BTU/h @ 240 volts 16,390 24,925 10,240 16,390 24,925 33,460 Blower Diameter 9" 9" 10" 10" 10" 10" Width 6" 6" 6" 6" 6" 6" Coil Drain Connection FPT 3/4" 3/4"...
  • Page 30 BLOWER PERFORMANCE DATA AWUF CFM deliverd against External Static Pressure Model Speed 0.1" 0.2" 0.3" 0.4" 0.5" High AWUF18XX1/16A* High AWUF18XX16B* High AWUF24XX1/16A* High AWUF24XX16B* 1250 1195 1135 1085 1010 High AWUF30XX1/16A* 1110 1055 1020 1255 1120 1100 1020 High AWUF30XX16B* 1115 1010...
  • Page 31: Wiring Diagrams

    WIRING DIAGRAMS ACNF HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 32 WIRING DIAGRAMS ADPF, ARPF, ARUF, ATUF HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. HTR1 HTR2 HTR1 HTR1 HTR2...
  • Page 33 WIRING DIAGRAMS ADPF, ARPF, ARUF, ATUF HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. HTR1 HTR2 HTR1 HTR1 HTR2...
  • Page 34 WIRING DIAGRAMS AEPF HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. HTR1 HTR2 HTR1 HTR1 TL HTR2 HTR1 TL HTR2 HTR3 HTR3 TL...
  • Page 35 WIRING DIAGRAMS AEPF******CA HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. HTR 1 HTR 1 HTR 1 HTR 1 HTR 2 PL 1 HTR 2...
  • Page 36 WIRING DIAGRAMS ASPF******AA HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 37 WIRING DIAGRAMS ASPF******BA HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 38 WIRING DIAGRAMS ASPF******CA HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. HTR1 HTR1 HTR1 HTR2 HTR1 HTR2 HTR2 HTR3 HTR3 HTR4 FOUR (4) ELEMENT ROWS...
  • Page 39 WIRING DIAGRAMS ASPF******C* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 40 WIRING DIAGRAMS AWUF [18, 24, 30, 36]** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 41 WIRING DIAGRAMS AWUF[31-32]** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
  • Page 42 WIRING DIAGRAMS AWUF37 HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.