Heat Kit Data - Goodman AVPTC 24B14A Series Manual

Multi-position, variable-speed ecm based air handler with internal txv comfortnet compatible

Advertisement

Models
Amps
AVPTC24B14A*
0.0/0.0
HKS*03XC*
10.8/12.5
HKS*05XC*
17.3/20.0
HKS*06XC*
21.7/25.0
HKS*08XC*
28.9/33.3
HKS*10XC*
34.7/40.0
AVPTC30C14A*
0.0/0.0
HKS*03XC*
10.8/12.5
HKS*05XC*
17.3/20.0
HKS*06XC*
21.7/25.0
HKS*08XC*
28.9/33.3
HKS*10XC*
34.7/40.0
AVPTC36C14A*
0.0/0.0
HKS*03XC*
10.8/12.5
HKS*05XC*
17.3/20.0
HKS*06XC*
21.7/25.0
HKS*08XC*
28.9/33.3
HKS*10XC*
34.7/40.0
HKSX15XF*
0.0/0.0
HKSX20XF*
0.0/0.0
HKSC15*#*
34.7/40.0
HKSC19C#*
34.7/40.0
HKSC15XF*
0.0/0.0
AVPTC42D14A*
0.0/0.0
HKS*03XC*
10.8/12.5
HKS*05XC*
17.3/20.0
HKS*06XC*
21.7/25.0
HKS*08XC*
28.9/33.3
HKS*10XC*
34.7/40.0
HKSX15XF*
0.0/0.0
HKSX20XF*
0.0/0.0
HKSC15*#*
34.7/40.0
HKSC20D#*
34.7/40.0
HKSC15XF*
0.0/0.0
HKSC20XF*
0.0/0.0
AVPTC48C14AA
0.0/0.0
HKS*03XC*
10.8/12.5
HKS*05XC*
17.3/20.0
HKS*06XC*
21.7/25.0
HKS*08XC*
28.9/33.3
HKS*10XC*
34.7/40.0
HKSX15XF*
0.0/0.0
HKSX20XF*
0.0/0.0
HKSC15*#*
34.7/40.0
HKSC19C#*
34.7/40.0
HKSC15XF*
0.0/0.0
All ampacities noted above include air handler motor amps
Circuit 1: Single-phase for Air Handlers / Circuit 2: Three-phase for HKR3 Heater Kits
¹
Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25
²
Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps
* Revision level that may or may not be designated
SS-GAVPTC
Circuit 1
MCA¹
MOP²
4.9/4.9
15/15
18/21
20/25
27/30
30/30
32/36
35/40
41/47
45/50
48/55
50/60
4.9/4.9
15/15
18/21
20/25
27/30
30/30
32/36
35/40
41/47
45/50
48/55
50/60
6.5/6.5
15/15
20/22
20/25
28/32
30/35
34/38
35/40
43/48
45/50
50/57
50/60
6.5/6.5
15/15
30.0/34.6
6.5/6.5
15/15
37.5/43.3
50/57
50/60
17.3/20.0
50/57
50/60
34.7/40
6.5/6.5
15/15
30.0/34.6
6.5/6.5
15/15
20/22
20/25
28/32
30/35
34/38
35/40
43/48
45/50
50/57
50/60
6.5/6.5
15/15
30.0/34.6
6.5/6.5
15/15
37.5/43.3
50/57
50/60
17.3/20.0
50/57
50/60
34.7/40
6.5/6.5
15/15
30.0/34.6
6.5/6.5
15/15
37.5/43.3
6.5/6.5
15/15
20/22
20/25
28/32
30/35
34/38
35/40
43/48
45/50
50/57
50/60
6.5/6.5
15/15
30.0/34.6
6.5/6.5
15/15
37.5/43.3
50/57
50/60
17.3/20.0
50/57
50/60
34.7/40
6.5/6.5
15/15
30.0/34.6
C = Circuit Breaker Option
--- indicates Not Required
• Only applicable when HKA kits are included in table
• MBVC and MBR models
www.goodmanmfg.com
Circuit 2
Amps
MCA¹
MOP²
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
38/43
40/45
47/54
50/60
22/25
25/25
43/50
45/50
38/43
40/45
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
38/43
40/45
47/54
50/60
22/25
25/25
43/50
45/50
38/43
40/45
47/54
50/60
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
38/43
40/45
47/54
50/60
22/25
25/25
43/50
45/50
38/43
40/45
HKA meets the new UL1995 requirements for 15 and 20KW heaters

Heat Kit Data

Single-Point Kit
MCA¹
MOP²
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
72/82
80/90
93/107
100/110
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
72/82
80/90
93/107
100/110
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
72/82
80/90
93/107
100/110
---
---
7