Charging; Electric Heat Kit Testing - Goodman MBVC 1 Series Installation Instructions Manual

Blower cabinet
Table of Contents

Advertisement

Non-Communicating Two Stage A/C
Figure 11
Non-Communicating SIngle Stage Heat Pump
Figure 12
Non-Communicating Two Stage Heat Pump
2. Download the CoolCloud HVAC phone application.
Note: When new versions of Bluetooth Communication Software
and Air Handler Control Software are available, the phone appli-
cation notifies the user. Software updates are classified as either
optional or mandatory and installed by using the phone application.
Ensure all mandatory software updates have been installed. Review
notes for optional software updates and install if necessary.
3. Go to the Non-Comm Outdoor Setting Menu () using
the on board push buttons or the CoolCloud HVAC phone
application. Select "" for single stage Air Conditioners,
"" for single stage Heat Pumps, "" for two stage Air
Conditioners and "" for 2 stage Heat Pumps.
4. Go to the Tonnage Units Menu () and select the tonnage
value that corresponds to the desired airflow for the outdoor
unit. See the following table.
NOTE: For the two stage non-communicating outdoor units, system
will stage airflow automatically for low stage operation.
Tonnage
Tonnage
Airflow
Selection
Selection
1
400
2.3
1.1
440
2.4
1.2
480
2.5
1.3
520
2.6
1.4
560
2.7
1.5
600
2.8
1.6
640
2.9
1.7
680
3
1.8
720
3.1
1.9
760
3.2
2
800
3.3
2.1
840
3.4
2.2
880
3.5
NOTE: The system will not provide airflows above the max Airflow
Value.
9
Figure 13
Tonnage
Tonnage
Airflow
Airflow
Selection
Selection
920
3.6
1440
4.9
960
3.7
1480
5
1000
3.8
1520
5.1
1040
3.9
1560
5.2
1080
4
1600
5.3
1120
4.1
1640
5.4
1160
4.2
1680
5.5
1200
4.3
1720
5.6
1240
4.4
1760
5.7
1280
4.5
1800
5.8
1320
4.6
1840
5.9
1360
4.7
1880
6
1440
4.8
1920
Airflow
1960
2000
2040
2080
2120
2160
2200
2240
2280
2320
2360
2400