Goodman RS6200006 Installation And Operationg Instructions

Goodman RS6200006 Installation And Operationg Instructions

Hide thumbs Also See for RS6200006:

Advertisement

ARUF**14**/ARPT**14**
ASPT**14**/ASUF**14**
AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS
1 Important Safety Instructions .................................................. 1
2 Shipping Inspection ................................................................ 2
2.1 Parts .............................................................................. 2
2.2 Handling ........................................................................ 3
3 Codes & Regulations .............................................................. 3
4 Replacement Parts ................................................................. 3
5
Pre-Installation Considerations .............................................. 3
5.1 Preparation .................................................................... 3
5.2 System Matches ............................................................ 3
5.3 Interconnecting Tubing .................................................. 3
5.4 Clearances .................................................................... 3
5.5 Horizontal Applications .................................................. 3
6
Installation Location ............................................................... 3
6.1 Upflow Installation ......................................................... 4
6.2 Horizontal Left Installation ............................................. 4
6.3 Downflow/Horizontal Right Installation .......................... 4
7 Refrigerant Lines .................................................................... 6
7.1 Tubing Size ................................................................... 6
7.2 Tubing Preparation ........................................................ 6
7.3 Special Instructions ....................................................... 6
7.5 Tubing Connections for TXV Models ............................. 7
8 Condensate Drain Lines ......................................................... 7
9 Ductwork ................................................................................. 8
9.1 Return Ductwork ........................................................... 8
10 Return Air Filters ................................................................... 8
11 Electric Heat ......................................................................... 8
11.1 No Electric Heat Installed ............................................ 9
12 Electrical and Control Wiring .............................................. 10
12.2 Wire Sizing ............................................................... 10
12.5 Low Voltage Connections ......................................... 11
12.5.1 Thermostats ......................................................... 11
12.6 Speed Tap Adjustment .............................................. 11
13 Achieving 2% Low Leakage Rate ....................................... 12
14 Start-Up Procedure ............................................................. 12
15 Regular Maintenance ......................................................... 12
Airflow Data ................................................................................ 13
Schematics ................................................................................ 15
Wiring Diagrams ........................................................................ 21
IO-427G
10/2013
It is your responsibility to install the product safely and to educate the customer on its safe use.
ATTENTION INSTALLING PERSONNEL
Prior to installation, thoroughly familiarize yourself with this Installation Manual.
Observe all safety warnings. During installation or repair, caution is to be observed.
RECOGNIZE THIS SYMBOL
AS A SAFETY PRECAUTION.

1 Important Safety Instructions

The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards. It
is the owner's and installer's responsibility to read and com-
ply with all safety information and instructions accompanying
these symbols. Failure to heed safety information increases
the risk of personal injury, property damage, and/or product
damage.

Advertisement

Table of Contents
loading

Summary of Contents for Goodman RS6200006

  • Page 1: Table Of Contents

    ARUF**14**/ARPT**14** ASPT**14**/ASUF**14** AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS 1 Important Safety Instructions ..........1 2 Shipping Inspection ..............2 2.1 Parts ................2 2.2 Handling ................ 3 3 Codes & Regulations .............. 3 4 Replacement Parts ..............3 Pre-Installation Considerations ..........3 5.1 Preparation ..............
  • Page 2: Shipping Inspection

    HIGH VOLTAGE! To prevent the risk of property damage, personal Disconnect ALL power before servicing. injury, or death, do not store combustible materials or Multiple power sources may be present. use gasoline or other flammable liquids or vapors in Failure to do so may cause property damage, the vicinity of this unit.
  • Page 3: Handling

    Refer to Re- applicable national codes. Installation in accordance with such mote Cooling/Heat Pump Service Manual RS6200006, codes and/or prevailing local codes/regulations is the respon- and TP-107 Long Line Set Application R-410A for tub- sibility of the installer.
  • Page 4: Upflow Installation

    6.1 Upflow Installation MODEL LIST FOR DOWNFLOW KITS No field modifications are mandatory however to obtain DFK-B DFK-C DFK-D maximum efficiency, the horizontal drip shield must be Downflow Kit Downflow Kit Downflow Kit removed. ARUF18B14** ARUF30C14** ARUF48D14** Drip Shield Removal: Refer to Figure 1, remove the two ARUF24B14** ARUF36C14** ARUF60D14**...
  • Page 5 Upper Tie Plate Control Deck Downflow Bracket Center Support Filter Bracket Filter Access Panel INTERNAL PART TERMINOLOGY Figure 6 UPFLOW DOWNFLOW NOTE: If removing only the coil access panel from the unit, Figure 2 Figure 3 the filter access panel must be removed first. Failure to do so will result in panel damage.
  • Page 6: Refrigerant Lines

    7 Refrigerant Lines Coil Slides on the downflow bracket This product is factory-shipped with R410A and dry nitrogen mixture gas under pressure. Use appropriate service tools and follow these instructions to prevent injury. A quenching cloth is strongly recommended to prevent scorching or marring of the equipment finish when brazing close to the painted surfaces.
  • Page 7: Tubing Connections For Flowrator Model

    NOTE: The use of a heat shield is strongly recom- 7. Braze tailpiece to the line set liquid tube and braze suc- mended when brazing to avoid burning the serial plate tion line connection. Quench all brazed joints with a or the finish of the unit.
  • Page 8: Ductwork

    A secondary condensate drain connection has been provided Use of a condensate removal pump is permitted when nec- for areas where the building codes require it. Pitch all drain essary. This condensate pump should have provisions for lines a minimum of 1/4" per foot to provide free drainage. shutting off the control voltage should a blocked drain occur.
  • Page 9: No Electric Heat Installed

    If no electric heat accessory kit is installed, a cover plate must be installed over the opening for electric heat. This ® ® cover plate kit is available from Goodman , Amana 1170 1170 1170 1170 1345 1345 Daikin brand distributors.
  • Page 10: Electrical And Control Wiring

    HEATER (kW) *ASUF HIGH VOLTAGE! To avoid property damage, personal injury or death due to electrical shock, this unit MUST have an 1170 1170 1170 1170 1345 1345 uninterrupted, unbroken electrical ground. The 1170 1170 1170 1170 1345 1345 electrical ground circuit may consist of an appropriately sized electrical wire connecting the 1590 1590...
  • Page 11: Electrical Connections - Supply Voltage

    12.4 Electrical Connections – Supply Voltage 12.5 Low Voltage Connections IMPORTANT NOTE: USE COPPER CONDUCTORS Several combinations of low voltage schemes are pos- ONLY. sible, depending on the presence of a heat kit and whether the heat kit is single-stage or multi-stage, Knockouts are provided on the air handler top panel whether the outdoor section is an air conditioner or heat and sides of the cabinet to allow for the entry of the...
  • Page 12: Achieving 2% Low Leakage Rate

    13 Achieving 2% Low Leakage Rate 15 Regular Maintenance Ensure all the gaskets remain intact on all surfaces as shipped with the unit. These surfaces are areas between the upper tie plate and coil access panel, blower access and coil ac- HIGH VOLTAGE! cess panels, and between the coil access and filter access Disconnect ALL power before servicing or...
  • Page 13: Airflow Data

    Airflow Data Static Pressure (in w.c) Blower Model Number Speed High 1150 1095 1045 1025 ARUF18B14* Medium High 1150 1095 1045 1025 ARUF24B14* Medium High 1145 1085 1020 ARUF30B14* Medium High 1485 1435 1385 1345 1275 1205 1125 ARUF30C14* Medium 1300 1270 1235...
  • Page 14 Airflow Data Blower Static Pressure (in w.c) Model Number Speed ASPT24B14 1050 1005 ASPT30C14 1440 1440 1400 1380 1350 1330 1295 1275 1245 1205 1060 1010 ASPT36C14 1150 1100 1090 1025 1250 1220 1205 1145 1110 1070 1035 1470 1440 1425 1405 1375...
  • Page 15: Schematics

    Schematics HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. WARNING MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. ROOM THERMOSTAT #18 GA. 4 WIRES WITH COOLING 3 WIRES WITHOUT AR UNIT GREEN WHITE TO CONDENSING...
  • Page 16 HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. WARNING MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. ARUF**14**/ARPT**14** 18-60 10 KW & BELOW TYPICAL H/P HEAT PUMP #18 GA. 7 WIRE ROOM THERMOSTAT AT/AR UNIT Y O C...
  • Page 17 ASPT/ASUF Thermostat Connections IMPORTANT: WHEN MATCHING THE ASPT AIR HANDLERS TO A SINGLE SPEED COOLING OR The following composite wiring diagrams detail various con- HEAT PUMP UNIT, REMEMBER TO CONNECT “Y” figurations in which the ASPT/ASUF air handlers can be used. FROM THE THERMOSTAT TO THE “Y2”...
  • Page 18 HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. WARNING MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. #18 GA. 5 WIRES WITH COOLING 4 WIRES WITHOUT ASPT UNIT ASUF UNIT CONDENSING UNIT 24V CONNECTION COOLING UNIT WITH OPTIONAL HEAT KITS OF 15 kW AND ABOVE AND ROOM THERMOSTAT WITH TWO STAGES OF HEAT...
  • Page 19 HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. WARNING MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. #18 GA. 7 WIRE ASPT UNIT ASUF UNIT HEAT PUMP UNIT WITH OPTIONAL HEAT KITS OF 15 kW AND ABOVE NOTES: NOMENCLATURE: COLOR CODES...
  • Page 20 HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. WARNING MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. ELECTRONIC BLOWER TIME DELAY RELAY TSTAT 120/240VAC SYSTEM XFMR-R PARK TERMINAL TRANSFORMER MOTOR NEUTRAL 24 VAC B13707-35 XFMR-C...
  • Page 21: Wiring Diagrams

    Wiring Diagrams HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. WARNING MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. ARUF**14**/ARPT**14** HTR1 HTR2 HTR1 HTR1 HTR2 HTR1 TL HTR2 HTR3 HTR3 HTR4 ONE (1) ELEMENT ROWS TWO (2) ELEMENT ROWS THREE (3) ELEMENT ROWS...
  • Page 22 Wiring Diagrams HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. WARNING MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. ASPT**14**/ASUF**14** HTR1 HTR1 HTR1 HTR 1 HTR2 HTR2 HTR2 HTR3 HTR3 HTR4 L1 L2 ONE (1) ELEMENT ROWS TWO (2) ELEMENT ROWS...
  • Page 23 HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. WARNING MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. 3-Phase Heat Kit 25kW Heat Kit HTR1 COMPONENT CODE COLOR CODE PC = 9 PIN CONNECTOR BK = BLACK HTR2 HTR = HEATER ELEMENT...
  • Page 24 • Parts • Financing Options 5151 San Felipe, Suite 500, Houston, TX 77056 © 2012 - 2013 Goodman Manufacturing Company, L.P. is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved.