AIR HANDLER HOMEOWNER'S ROUTINE MAINTENANCE RECOMMENDATIONS
We strongly recommend a bi-annual maintenance checkup be performed
before the heating and cooling seasons begin by a qualified servicer.
REPLACE OR CLEAN FILTER
IMPORTANT NOTE: Never operate unit without a filter installed
as dust and lint will build up on internal parts resulting in loss of
efficiency, equipment damage and possible fire.
An indoor air filter must be used with your comfort system. A
properly maintained filter will keep the indoor coil of your com-
fort system clean. A dirty coil could cause poor operation and/or
severe equipment damage.
Your air filter or filters could be located in your furnace, in a blower
unit, or in "filter grilles" in your ceiling or walls. The installer of
your air conditioner or heat pump can tell you where your filter(s)
are, and how to clean or replace them.
Check your filter(s) at least once a month. When they are dirty,
replace or clean as required. Disposable type filters should be
replaced. Reusable type filters may be cleaned.
You may want to ask your dealer about high efficiency filters. High
efficiency filters are available in both electronic and non-electronic
types. These filters can do a better job of catching small airborne
particles.
MOTORS
Indoor and outdoor fan motors are permanently lubricated and
do not require additional oiling.
ALUMINUM INDOOR COIL CLEANING
(QUALIFIED SERVICER ONLY)
This unit is equipped with an aluminum tube evaporator coil. The
safest way to clean the evaporator coil is to simply flush the coil
with water. This cleaning practice remains as the recommended
cleaning method for both copper tube and aluminum tube resi-
dential evaporator coils.
It has been determined that many coil cleaners and drain pan tab-
lets contain corrosive chemicals that can be harmful to aluminum
tube and fin evaporator coils. Even a one-time application of these
corrosive chemicals can cause premature aluminum evaporator
coil failure. Any cleaners that contain corrosive chemicals including,
but not limited to, chlorine and hydroxides, should not be used.
AIR HANDLER
An alternate cleaning method is to use one of the products listed in
TP-109* to clean the coils. The cleaners listed are the only agents
deemed safe and approved for use to clean round tube aluminum
coils. TP-109 is also available on the web site in Partner Link >
Service Toolkit.
NOTE: Ensure coils are rinsed well after use of any chemical clean-
ers.
BEFORE YOU CALL YOUR SERVICER
Check the thermostat to confirm that it is properly set.
Wait 15 minutes. Some devices in the outdoor unit or
in programmable thermostats will prevent compressor
operation for awhile, and then reset automatically. Also,
some power companies will install devices which shut off
air conditioners for several minutes on hot days. If you wait
several minutes, the unit may begin operation on its own.
Check the electrical panel for tripped circuit breakers or
failed fuses. Reset the circuit breakers or replace fuses as
necessary.
Check the disconnect switch near the indoor furnace or
blower to confirm that it is closed.
Check for obstructions on the outdoor unit . Confirm that
it has not been covered on the sides or the top. Remove
any obstruction that can be safely removed. If the unit is
covered with dirt or debris, call a qualified servicer to clean
it.
Check for blockage of the indoor air inlets and outlets.
Confirm that they are open and have not been blocked by
objects (rugs, curtains or furniture).
Check the filter. If it is dirty, clean or replace it.
Listen for any unusual noise(s), other than normal operating
noise, that might be coming from the outdoor unit. If you
hear unusual noise(s) coming from the unit, call a qualified
servicer.