PUSH BUTTON MENUS

Note: When installed with an inverter outdoor unit, any change made to the inverter default settings must be made using the push
button on the outdoor unit control board. See inverter unit installation manual for push button menu instructions.
LED Display
View 6 most recent fault codes and Clear Fault Codes if desired

(furnace)
Restart communications between the indoor and outdoor unit.

Control Firmware Revision Number


Control Shared Data Revision Number

Constant Fan Speed as percent of maximum airflow. Default = 30%
Electric Heater Kit Wattage (kW)


Electric Heat Off Delay (seconds)
Electric Heat On Delay (seconds)


Electric Heat Airflow Trim (percentage)
Percentage of high stage electric heating airflow to run duirng low

stage electric heat operation
1 = system will try to satisfy the thermostat quickly.

5 (default) = system will try to satsify the thermostat more slowly.
Select "" to enable dehumidification when the thermostat DH

terminal is energized. Select "" to enable dehumidification when
the thermostat DH terminal is de-energized. (default = )
Select number of stages for the non-communicating outdoor unit.
( for single-stage Air Conditioners,  for single stage Heat

Pumps,  for two stage Air Conditioners or  for two stage heat
pumps)
Indoor Airflow for non-communicating outdoor units. (values based

on 400CFM per ton) (default = 3.0 Ton)

Cooling Airflow Trim (default 0%)
Cooling Airflow Profile setting (default = profile D shown as 4)

Cooling Airflow On Delay Time (default = 5 seconds)

Cooling Airflow Off Delay Time. (default = 60 seconds)

Percentage of high stage cooling airflow to run during low stage

operation. (default = 70%)
Electric heat operation during defrost. 1 = low stage 2 (default) =

high stage
Heat Pump Indoor Airflow Trim (default = 0%)


Heat Pump Heating Airflow Off Delay Time (default = 60 seconds)
Heat Pump Heating Airflow On Delay Time (default = 5 seconds)

Percentage of high stage heat pump heating airflow to run during

low stage operation. (defaullt = 70%)
When heat pump heating and electric heat are running at the same

time, this percentage is used for additional airflow trim
Enables or disables dehumidification feature in the outdoor unit.

(default = Enabled)
Balance point temperature. The Compressor will not operate below

temperature. (Default = 0°F)

Backup Heat Balance Points
Compressor run time between defrost cycles. (default = 30 minutes)

(2 stage units)
Compressor off delay at the beginning and end of a defrost cycle.

(default = 30 seconds)
Menu Descrip�on