Problems - Causes - Solutions - Saeco Royal OTC SUP060 Operation And Maintenance

Table of Contents

Advertisement

11.2

Problems - Causes - Solutions

The following table indicates the possible error or alarm causes which may lead to a partial or total shutdown of the
appliance.
Error code
Error 01:
E01
GRINDER_FAIL
GRINDER LOCKED
It indicates that there is a grinder failure.
Coffee grinder broken or not working properly.
E03
Error 03:
BU_FWD_FAIL
BREWING UNIT LOCKED IN WORK POSITION
It indicates that the brewing unit failed to reach the WORK position.
E04
Error 04:
BU_RWD_FAIL
BREWING UNIT LOCKED IN HOME POSITION
It indicates that the brewing unit failed to reach the HOME position.
E05
Error 05:
CIRCUIT_CLOGGED_FAIL
HYDRAULIC CIRCUIT REFILL FAILED
Indicates a fault regarding the water circuit for hot water/coffee:
the pump fails to refill the hydraulic circuit.
E06
Error 06:
DC_VALVE_FAIL
DC VALVE SHORT CIRCUIT
It indicates the solenoid valve short circuit
E07
Error 07:
DOSER_FAIL
BATCHER MICROSWITCH BLOCKED
It indicates that the batcher microswitch is blocked or not working properly
E10
Error 10:
HEATER_SHORT_CIRCUIT_TEMP_SENSOR_FAIL
SHORT CIRCUIT BOILER COFFEE TEMPERATURE SENSOR
Indicates that the NTC temperature sensor of the coffee boiler is in short-circuit
E11
Error 11:
HEATER_OPEN_LOOP_TEMP_SENSOR_FAIL
OPEN LOOP BOILER COFFEE TEMPERATURE SENSOR
Indicates that the NTC temperature sensor of the coffee boiler is not connected
E14
Error 14:
HEATING_UP_TIMEOUT_FAIL
TIMEOUT BOILER
It indicates that the coffee boiler supply is not connected.
E16
Error 16:
BU_SHORT_CIRCUIT_FAIL
BREWING UNIT SHORT CIRCUIT
It indicates a short circuit in the brewing unit gearmotor.
E19
Error 19:
ZERO_CROSSING_FAIL
ZERO CROSSING ERROR
It indicates a stability problem in the mains frequency that supplies the machine.
E20
Error 20:
HEATING_UP_OVER_TEMP_FAIL
OVER TEMP BOILER
It indicates that the boiler has reached an excessive temperature and has been forcibly switched off.
Description
English
77

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents