Saeco Royal OTC SUP060 Operation And Maintenance page 68

Table of Contents

Advertisement

English
Remove the brew group by pulling it by the handle and
pressing the «PRESS» button. The brew group must be
washed with lukewarm water only. Do not use any detergent.
Wash the brew group with lukewarm water; carefully
wash the upper filter. Before placing the brew group in its
seat, ensure that there is no water left in the brewing
chamber.
Make sure that the brew group is in the off position. The
two reference marks must match.
If they do not match, proceed as described below:
Ensure that the lever is in contact with the brew group
base.
68
Make sure that the hook which locks the brew group is in
the correct position. firmly press the "PRESS" button to
check its position.
Insert the brew group into its seat again until it locks into
place WITHOUT pressing the "PRESS" button.
Close the service door.
Ensure
that
group is completely dry
before putting it back into
the machine.
10.2.7
Brew Group Cleaning with
the "Coffee Oil Remover"
Besides weekly cleaning, we recommend performing a
cleaning cycle with "Coffee Oil Remover" after approximately
500 cups of coffee or once a month. This operation
completes the maintenance process for the brew group.
Both the "Coffee Oil Remover" system used to clean the
brew group and the "Maintenance Kit" may be purchased
at your local dealer or at authorised service centres.