Temperature - VeriFone UX300 Installation Manual

Hide thumbs Also See for UX300:
Table of Contents

Advertisement

S
PECIFICATIONS
Temperature •
NOTE
34
UX300 I
NSTALLATION
Typical Power: 3 W (CTLS read), 4W (UX100 display heater), 0.5W (UX100/
110), 5W (RS232-vout)
Sleep Mode: Approximately 30 to 50 mW, wakeup time 7 sec.
UX300-MDB, UX300-PSTN, UX300-ISDN, UX300-GPRS, UX300-LAN, UX300-
WPWR
Operation voltage: 9 V DC to 43 V DC
Idle Power: 4 W
Typical Power: 3 W (CTLS read), 4 W (UX100 display heater), 0.5 W (UX100/
110), 5 W (RS232-vout),
10W(USB-Master), 3 W (GPRS connect)
Sleep Mode: Approximately 30 to 50 mW, wakeup time 7 sec.
UX300-Petrol
Operation voltage: 24 V DC
Idle Power: 4 W
Typical Power: 3 W (CTLS read), 4 W (UX100 display heater), 0.5 W (UX100/
110), 5 W (RS232-vout),
10W(USB-Master), 70 W (printer)
Sleep Mode: Approximately 30 to 50 mW, wakeup time 7 sec.
Operating temperature:
-20°C to 70°C (-4°F to 158°F) Standard unit
-20°C to 65°C (-4°F to 149°F) MDB, LAN, Petrol units
0°C to 65°C (32°F to 149°F) PSTN, ISDN units
Storage temperature: -25°C to 70°C (-13°F to 158°F)
Power Supply rated for indoor use only: 12 V DC 3.3A, operating temperature
0°C to 40°C (32°F to 104°F)
Power Supply rated for outdoor use: 24 V, DC 3.75 A up to 40°C (DC 2.5 A up
to 60°C), operating temperature -25°C to 60°C
Relative humidity: 5% to 90% RH non-condensing
If this device is to be used in the Nordic countries, or in any environment where
the temperature range exceeds the product's operating temperature, it is the
responsibility of the integrators to ensure that the ambient environment is
controlled in such a way to ensure that the product operates within the specified
temperature range.