Hide thumbs Also See for UX301:

Advertisement

Quick Links

UX301
Installation Guide
Verifone Part Number DOC159-026-EN-C, Revision C

Advertisement

Table of Contents
loading

Summary of Contents for VeriFone UX301

  • Page 1 UX301 Installation Guide Verifone Part Number DOC159-026-EN-C, Revision C...
  • Page 2 Verifone, Inc. The information contained in this document is subject to change without notice. Although Verifone has attempted to ensure the accuracy of the contents of this document, this document may include errors or omissions. The examples and sample programs are for illustration only and may not be suited for your purpose.
  • Page 3: Table Of Contents

    Caution and UX301 Caution and Warning Messages ......39 Warning Messages...
  • Page 4 ONTENTS UX301 I NSTALLATION UIDE...
  • Page 5: Reface

    Related To learn more about the card reader and controller device, refer to the following Documentation set of documents and their associated Verifone Part Numbers (VPNs). UX301 Certifications and Regulations Sheet VPN DOC159-024-EN UX401 Certifications and Regulations Guide VPN DOC159-034-EN...
  • Page 6 Radio Frequency RJ45 Registered Jack 45 modular connector RS-232 Recommended Standard 232 Request to Send Secure Access Module SubMiniature version A connector SRED Secure Reading and Exchange of Data Universal Serial Bus Vending Machine Wide Area Networks UX301 I NSTALLATION UIDE...
  • Page 7: Features And Benefits

    Expresspay2 and Discovery. Device Capabilities The UX301 is a main control unit device as well as a magnetic card reader and smart card reader. This unit connects to vending machines, PCs, and is intended to connect to peripheral units such as PIN pads, CTLS antennae and external printers.
  • Page 8 EVICE VERVIEW Features and Benefits UX301 I NSTALLATION UIDE...
  • Page 9 HAPTER Setup This chapter describes the setup procedures for the UX301 card reader and controller, under the following sections: • Selecting Unit Location • Unpacking the Shipping Carton • Examining the Unit’s Features • ARS and Service Switches • Installing or Replacing SAM Cards •...
  • Page 10: Selecting Unit Location

    Make sure the installation method does not invalidate the Anti-Removal Switch CAUTION (ARS) function. Do not, for instance, install the UX301 in a sub-chassis that can be removed from the main cabinet. NOTE The front panel of the device meets the IP34 standards for installation under outdoor environments.
  • Page 11: Examining The Unit's Features

    CARD READER SLOT LEDS MOUNTING MOUNTING STUD HOLES STUD HOLES ANTI-REMOVAL SWITCHES (ARS) Figure 1 UX301 Front View Front Features The front of the reader shows the following: • Customer-view indicator LEDs • The card reader slot • Anti-removal switches •...
  • Page 12 SMA (analog RF) CTLS / NFC antenna connector • 3 SAM card slots • Model-dependent board features: • MDB power port (9 to 43V DC). RF PORT USB (CLIENT) PORT SAM CARD UX401 SLOTS CONNECTION PORT SERVICE SWITCH Figure 3 UX301 Top View UX301 I NSTALLATION UIDE...
  • Page 13: Ars And Service Switches

    Please contact your Verifone representative for details. Make sure the installation method does not invalidate the Anti-Removal Switch CAUTION (ARS) function. Do not, for instance, install the UX301 in a sub-chassis that can be removed from the main cabinet. System Mode...
  • Page 14 SAM CARD 2 NOTCH FACES RIGHT (GOLD CONTACTS FACE DOWN) SAM CARD 3 NOTCH FACES LEFT (GOLD CONTACTS FACE UP) Figure 6 SAM Slots and Card Orientation Install additional SAM cards in the available slots as necessary. UX301 I NSTALLATION UIDE...
  • Page 15: Cable Connections

    This section discusses the connection of the UX301 device with the following host UX-Series Host units: Device Connecting to a Vending Machine You can connect the UX301 to a host vending machine (VM) with any of the following connection types: • USB Type B •...
  • Page 16 Figure 7 Connecting to a UX110 PIN Pad Connect the Type A plug in the UX301 high-powered port and connect the type B plug to the USB port of the UX110. Use the same procedure for connecting to other UX1xx-series PIN pads.
  • Page 17 ETUP Cable Connections To connect the UX301 Attach one end of the RJ45 plug cable to the UX301 and the other end to the to a UX401 CTLS unit UX401. Attach one end of the SMA cable to the UX301 and the other end to the UX401.
  • Page 18 ETUP Cable Connections To connect to a Disconnect the device from all power sources. TG-2460H Printer Connect the RS-232 cable to the UX301 printer port and connect the RJ45 plug to the printer. TG2460H Figure 9 Connecting TG-2460H Printer Cable Connect power to the printer using the CBL159-306-01-A and 28580-01-R cables.
  • Page 19: Mounting The Device

    Secure the unit with M5 nuts with a minimum length of 12 mm. Tighten the nuts using to the recommended torque of 7.0 kgfcm (6.1 lbf.in). You can also mount the UX301 using welded screw bolts on the inner side of the NOTE mounting plate.
  • Page 20: Grounding The Units

    (without any loops) to ensure smooth water drainage. Grounding the If you connect the UX301 to a UX-series PIN pad, use the following steps to Units ground your units.
  • Page 21: Connecting Power Supply

    Documentation. Using an incorrectly rated power supply can damage the unit or cause it to CAUTION malfunction. The power rating for UX301 is 9 V DC to 43 V DC. Verifone recommends the following PSUs: • 12 V, 3.3 A L5 EEF PSU for UX301 (VPN PWR159-001-01-A) •...
  • Page 22 ETUP Connecting Power Supply To connect to a power Connect the power cable to the power port on the UX301 and the other end to source your power source. Figure 13 Connecting Power to the UX301 UX301 I NSTALLATION UIDE...
  • Page 23: Using The Device

    Card transaction procedures vary depending on the application. Verify the proper procedure with your application provider before performing a card transaction. Using the Multi-Card The UX301 supports magnetic stripe cards as well as smart cards. Use the Reader following steps in conducting UX301 card transactions.
  • Page 24 ETUP Using the Device UX301 I NSTALLATION UIDE...
  • Page 25: Technical Specifications

    UX301 card reader. Technical Refer to the following information on the power, weight, temperature, memory, Specifications ports and other technical details about your UX301 card reader. Unit Power • Operation voltage: 9 to 43 V DC, 24 V DC for printer use Requirements •...
  • Page 26 8-PIN to RJ45 connector to UX401 CTLS antenna unit Model dependent board: • Communication • COM: Up to 115200 bps, HW RTS/CTS handshake • MDB: 9600 bps fix, 9E1. Optically isolated current loop. Display • 3 status LEDs on the front (payment application controlled). UX301 I NSTALLATION UIDE...
  • Page 27: Additional Safety Information

    These suggestions apply equally to your device, or any of its attachments or accessories. If your device is not working properly, take it to the nearest Verifone- authorized service provider for servicing or replacement. Additional The following is additional information for your safety in using this device.
  • Page 28 AINTENANCE AND LEANING Additional Safety Information UX301 I NSTALLATION UIDE...
  • Page 29: Service Returns

    International – Contact your Verifone representative. Service Returns Before returning the unit to Verifone, you must obtain a Merchandise Return Authorization (MRA) number. The following procedure describes how to return one or more card reading units for repair or replacement (U.S. customers only).
  • Page 30: Accessories And Documentation

    You will be issued MRA number(s) and the fax will be returned to you. NOTE One MRA number must be issued for each unit you return to Verifone, even if you are returning several of the same model. Describe the problem(s) and provide the shipping address where the repaired or replacement unit must be returned.
  • Page 31 South Africa power cord for PWR159-001-01-A PSU CPS12490-4A-R 24 V Rhino PSU for UX301 Petrol PWR159-001-01-A 12 V, 3.3 A L5 EEF power supply unit (PSU) for UX301 PWR159-002-01-A 12 V, 3.3 A L6 EEF power supply unit (PSU) for UX301 27556-10-R...
  • Page 32 ERVICE AND UPPORT Accessories and Documentation UX301 I NSTALLATION UIDE...
  • Page 33: Transactions Fail To Process

    Ensure that you are swiping cards properly. With the card reader, the black magnetic stripe should face down. NOTE The UX301 reads the card upon card removal or withdrawal from the slot. • If possible, process a transaction manually, using an external keypad, instead of the card reader.
  • Page 34 Ensure that the card is inserted correctly and that the card is not removed prematurely. • Ensure the SAM cards are properly inserted in the cardholders and that the cardholders are properly secured (see Installing or Replacing SAM Cards). • If the problem persists, contact your local Verifone representative. UX301 I NSTALLATION UIDE...
  • Page 35: Ux301 Port Pinouts

    HAPTER Port Pinouts This section contains port pinout tables for the UX301. UX301 Port Refer to the following UX301 port pinout diagrams. Pinouts RS-232 Port (COM1) Connector Function Description Portpwr (9 to12 PowerOut, max 1 A V DC) No connection...
  • Page 36 INOUTS UX301 Port Pinouts Ethernet Port Connector Function Description (LAN) TXD+ Transmit data + TXD- Transmit data - RXD+ Receive data + No connection No connection RXD- Receive data - No connection No connection USB Pinout Connector Function Description (Host Port)
  • Page 37 INOUTS UX301 Port Pinouts Power Port (DC-in or Applies to UX301 STD version. Printer) Connector Function Description +24 V External power from cable Power ground +24 V - Printer Power to TG-2460H printer Unused Unused GND - Printer Printer ground Power Port (DC-in or Applies to UX301 MDB version.
  • Page 38 INOUTS UX301 Port Pinouts UX301 I NSTALLATION UIDE...
  • Page 39: Ux301 Caution And Warning Messages

    Do not, for instance, install the (ARS). Ne pas, par exemple, installer la UX301 in a sub-chassis that can UX301 dans un sous- châssis qui peut be removed from the main cabinet. être retiré de l' armoire principale. Warning...
  • Page 40 The power des dysfonctionnements. La puissance rating for UX301 is 9 V DC to 43 V pour UX301 est 9 V DC à 43 V DC. Verifone recommande les UAR suivantes: Verifone recommends the following 12 V, 3.3 A L5 EEF PSU for UX301...
  • Page 41 AUTION AND ARNING ESSAGES UX301 Caution and Warning Messages UX301 I NSTALLATION UIDE...
  • Page 42 Verifone, Inc. Tel: 1-800-Verifone www.verifone.com UX301 Installation Guide Verifone Part Number DOC159-026-EN-C, Revision C...

Table of Contents