Sony PDW-U4 Service Manual page 52

Professional disc drive unit
Hide thumbs Also See for PDW-U4:
Table of Contents

Advertisement

Main
Sub
ERROR/ALARM indicator
Code
Code
Lighting
Switching off
interval
condition
6F
F00
1 second
Disc/Power
F03
0.25 seconds
Disc/Power
F80
1 second
Disc/Power
F83
0.25 seconds
Disc/Power
Description
Error remedy method
Startup adjustment or
1. Eject the cartridge.
OPC cannot be finished in
2. Check laser parameter 1 of hours meter.
optical block assembly
When laser parameter 1 of hours meter has:
1Ach.
• not reached the end of replacement cycle:
Go to step 3 in the error remedy method.
• reached the end of replacement cycle:
It is likely laser in optical block assembly (OP-1) reached to the end of
its life cycle.
Replace optical block assembly (OP-1).
Adjustment failed in
3. Insert again the ejected cartridge.
starting optical block
• In the case no error occurs:
assembly 1Ach.
The problem is fixed. Use the unit as it is.
• In the case the error occurs:
Go to step 4 in the error remedy method.
4. Insert another cartridge.
• In the case no error occurs:
Startup adjustment or
The ejected cartridge is likely to be faulty.
OPC cannot be finished in
Tip
optical block assembly
For how to handle the defective cartridge, contact your local Sony Sales
1Bch.
Office/Service Center.
• In the case the error occurs:
A drive fault is likely. Go to step 5 in the error remedy method.
5. Startup the maintenance menu and perform [CHECK] > [LENS
Adjustment failed in
CLEANING].
starting optical block
After [LENS CLEANING] is performed:
assembly 1Bch.
• when the symptom is improved,
The problem is fixed. Use the unit as it is.
• When the symptoms do not improve,
Replace optical block assembly (OP-1).
Refer to section
"2-1-1. Digital Hours Meter"
"2-1-2. Periodic Inspection
and Replacement Parts List"
"6-4-9. LENS CLEANING"
"4-5. Optical Block
Assembly"
49