You can use the system flags as Boolean valuables. If conditions are met, "1" (true) is automatically
assigned to a system flag. If conditions are not met, "0" (false) is assigned. You can refer to the
assigned values whenever necessary.
No.
Identifier
01 #FisCOM1
02 #FltCOM1
03 #FeqCOM1
04 #FgtCOM1
05 #FtimeOutCOM1
06 #FisCOM2
07 #FltCOM2
08 #FeqCOM2
09 #FgtCOM2
10 #FtimeOutCOM2
11 #FisCOM3
12 #FltCOM3
13 #FeqCOM3
14 #FgtCOM3
15 #FtimeOutCOM3
30 #FinitMecError
31 #FcameraError
32 #FtakeZError
33 #FlMoveOutRange Range status of relative move command
34 #FlMoveStop
35 #FcheckPosError
36 #FdataInBCDError Error status of dataInBCD command
60 #FstartSW
61 #FincSW
62 #FdecSW
Specifications

22. SYSTEM FLAG LIST

Description
Existence of COM1 received data
Comparison command (cmpCOM) result of
COM1 received data
Comparison command (cmpCOM) result of
COM1 received data
Comparison command (cmpCOM) result of
COM1 received data
Comparison command (cmpCOM) timeout of
COM1 received data
Existence of COM2 received data
Comparison command (cmpCOM) result of
COM2 received data
Comparison command (cmpCOM) result of
COM2 received data
Comparison command (cmpCOM) result of
COM2 received data
Comparison command (cmpCOM) timeout of
COM2 received data
Existence of COM3 received data
Comparison command (cmpCOM) result of
COM3 received data
Comparison command (cmpCOM) result of
COM3 received data
Comparison command (cmpCOM) result of
COM3 received data
Comparison command (cmpCOM) timeout of
COM3 received data
Mechanical initialization command error
status
Camera data acquisition error status
Z height adjustment (takeZWadj) acquisition
error status
Conditional stop status of relative move
command
Result of the position discrepancy detection
command
Start switch
Program number selection key (+)
Program number selection key (–)
118
Condition "1" (True)
Exists
Constant > Receive data
Constant = Receive data
Constant < Receive data
Timeout
Exists
Constant > Receive data
Constant = Receive data
Constant < Receive data
Timeout
Exists
Constant > Receive data
Constant = Receive data
Constant < Receive data
Timeout
Mechanical initialization error
Error
Error
Out of range
Stopped by the stop
condition
Position discrepancy error
Error
ON (pressed)
ON (pressed)
ON (pressed)
Desktop Robot JR3000