Sharp AR-6020V Service Manual page 80

Digital multifunctional system
Table of Contents

Advertisement

Unit name
Part name
Document
transport
Paper feed roller
section
(RSPF)
Pickup roller
Separation roller
Torque limiter
Discharge brush
Transportation rollers
Sensors
Reading plate
Gears
Belts
OC mat
Cassette
Pickup roller
paper feed
Paper feed roller
section
Separation roller
Torque limiter
Transportation rollers
Paper guides
Gears
<26/31 cpm>
Unit name
Part name
Drum periph-
OPC drum
eral
Cleaning blade
Side seal F/R
MC unit
Transfer roller
Transfer gear
Anti-static pin
Transfer bearing
Separation pawl unit
Star ring
Process frame unit
Developing
Developer
section
Toner filter
DV blade
Toner sensor
DV side seal F/R
Optical sec-
Mirrors/Lens/CCD
tion
Table glass/SPF glass
Scanner lamp
Rails
Drive belt/Drive wire
Sensors
OC
LSU
Dust-proof glass
Paper feed/
Pickup roller
transport
Separation roller
section
Transport rollers
Transport paper guide
Torque limiter
Gears
Sensors
When calling
75K
150K
O
O
O
O
O
O
O
O
O
X
X
X
X
X
X
O
O
O
X
X
X
O
O
O
X
X
X
X
X
X
O
O
O
X
O
O
X
O
O
X
O
O
X
X
X
X
O
O
O
O
O
X
X
X
When
100K
150K
200K
calling
-
X
-
X
X
X
X
X
X
X
-
O
O
-
X
-
X
-
X
-
X
-
X
-
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
O
O
O
O
O
O
O
O
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
O
O
O
O
X
X
X
X
X
O
O
O
X
O
O
O
X
O
O
O
O
O
O
O
X
X
X
X
X
X
X
X
X
X
X
X
AR-6020V MAINTENANCE 9 – 4
225K
300K
Replacement reference:
O
O
Replace according to the RSPF paper feed
counter value.
RSPF section roller: 100K or 1 years of use
O
O
When replacing the paper feed roller, apply
grease to the paper feed shaft. (GP-
501MR)
O
O
Replacement reference:
Replace according to the RSPF paper feed
X
X
counter value.
RSPF torque limiter: 400K or 2 years of use
X
X
O
O
X
X
O
O
X
X
X
X
O
O
O
O
O
O
Replace it every 100K or 1 year of use
O
O
X
X
O
O
O
O
X
X
Apply the grease to the necessary part.
300K
400K
450K
X
-
X
Replace as Process frame unit
-
X
X
every 300K.
-
X
O
Replace as Transfer roller unit.
-
X
-
-
X
-
-
X
-
-
X
Replace as Process frame unit
every 300K.
-
X
X
X
Process unit without the drum.
X
X
X
X
X
X
X
X
Check the sensor head surface.
X
X
X
O
O
O
O
O
O
X
X
X
Air-blow the light guide bar.
X
X
X
X
X
X
X
X
X
O
O
O
X
X
X
O
O
O
Replace it every 100K or 1 year of
use
O
O
O
O
O
O
O
O
O
X
X
X
X
X
X
X
X
X
Remark
Remark