Sharp AR-6020V Service Manual page 65

Digital multifunctional system
Table of Contents

Advertisement

: '19/Oct.
1
Main
Sub
code
code
50
Duplex copy rear edge void adjustment
19
(Duplex model only)
01
TC ON/OFF timing adjustment
02
Resist amount adjustment
51
1
<26/31 CPM only>
03
Used to adjust the operation timing of
the separate pawl.
<26/31 CPM only>
08
Used to disable the operation of the
separate pawl.
Contents
Used to adjust the rear edge void amount in duplex copy.
(Operating procedure)
When this simulation is executed, the current set value is displayed in two digits.
(Adjustment range: 1 - 99, Center value: 50)
*
When the set value is increased by 1, the void amount is increased by about 0.1mm.
Press the [AUTO/TEXT/PHOTO] key to select a suitable setting mode and a display. Enter the adjustment value
with the Numeric keys and press the [START] key, and the entered value is saved and a copy is made. (Paper
information is cleared after every copying).
When the [INTERRUPT] key is pressed, the entered value is saved and the machine goes into the sub code entry
standby mode. When the [CA] key is pressed, the entered value is saved and the simulation is terminated.
AUTO indicator
TEXT indicator
PHOTO indicator
When this simulation is executed, the current set value is displayed on the number of copies display.
(Adjustment range: 1 - 99, Center value: 50)
*
When the set value is increased by 1, the void amount is increased by about 0.22mm.
Enter the adjustment value with the Numeric keys and press the [START] key, and the entered number is written
into the EEPROM and the machine goes into the sub code entry standby mode.
Switching can be made with [AUTO/TEXT/PHOTO] key, and the set value of the selected mode is displayed on the
number of copies display.
When the [INTERRUPT] key is pressed at that time, machine goes into the sub code input standby mode. When
the [CA] key is pressed, the simulation mode is terminated.
AUTO indicator
TEXT indicator
Used to adjust the contact pressure of the machine resist roller and the RSPF resist roller onto the paper.
(Operating procedure)
When this simulation is executed, the current set value is displayed on the number of copies display.
When the [START] key is pressed, the following set items are changed sequentially. Enter an adjustment value with
the Numeric keys and press the [START] key, and the entered value will be saved and a copy will be made.
(Adjustment range: 1 ~ 99)
When the [CA] key is pressed, the entered value is saved and the simulation is terminated.
No.
1
Resist amount (Main unit cassette) (Plain paper)
2
Resist amount (2nd to 4th cassette) (Plain paper)
3
Resist amount (Second print surface) (Plain paper)
4
Resist amount (Manual feed tray) (Plain paper/Thin paper)
5
Resist amount (Manual feed tray) (Heavy paper 1)
6
Resist amount (Manual feed tray) (Heavy paper 2)
7
Resist amount (Manual feed tray) (Envelop)
8
Resist amount (Manual feed tray) (OHP)
9
Resist amount (Manual feed tray) (Label)
10
Resist amount (Manual feed tray) (Letter)
RSPF document resist amount (First print surface) (Low
11
speed)
RSPF document resist amount (First print surface) (Low
12
speed)
RSPF document resist amount (First print surface) (High
13
speed)
RSPF document resist amount (First print surface) (High
14
speed)
Supported for the installed models only. Skipped for the models without installation.
Adjust the operation timing of Separate pawl.
When executing the simulation, the current set value is indicated on the display.
When pressing [Start] key after entering the code number, the entered set value is stored on EEPROM.
The set value of the selected mode is indicated on the display and the set mode can be switched by [Copy Image
Quality Mode Select] key.
The entered set values are programmed in EEPROM.
Lighting LED
AUTO LED
TEXT LED
Select whether to disable the operation of the separate pawl or not.
Execute the simulation to indicate the code number currently set up.
Enter the code number and press [Start] key to switch the setting.
Code Number
LED
Paper rear edge void amount (First print surface)
Paper rear edge void amount (Second print surface)
Print start position (duplex back surface)
LED
TC ON TIMING
TC OFF TIMING
Contents
Time setting of Solenoid ON
Time setting of Solenoid OFF
0
ENABLE
1
DISABLE
AR-6020V SIMULATIONS 6-26
Details of operation
Item
Adjustment mode
Setting
Display
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Set mode
Setting
Default
33
56
52
Default
50
50
Range
Default
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
65
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50
1 - 99
50