code
Duplex motor forward rotation check
01
(Duplex model only)
Duplex motor reverse rotation check
02
(Duplex model only)
09
Duplex motor RPM adjustment
04
(Duplex model only)
Duplex motor switchback time
05
adjustment
(Duplex model only)
10
01
Toner motor operation
14
-
Trouble cancel (except for U2)
16
-
U2 trouble cancel
20
01
Maintenance counter clear
01
Maintenance cycle setting
21
Mini maintenance cycle setting (Valid
02
only when the destination is set to
Japan AB series.)
01
Maintenance counter display
Maintenance preset display (Valid only
02
when the destination is set to EX Japan)
22
03
Jam memory display
04
Jam total counter display
05
Total counter display
The duplex motor is driven in forward direction (in the paper exit direction) for 30 sec.
During the process, the display section displays the sub code.
After completion of the process, the machine goes into the sub code input standby mode.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The duplex motor is driven in reverse direction for 30 sec.
During the process, the display section displays the sub code.
After completion of the process, the machine goes into the sub code input standby mode.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
When any key input is made, it is displayed on the number of copies display.
When the [START] key is pressed, the set code data are acquired and stored in the EEPROM, and the machine
goes into the sub code input standby mode.
When, however, the [START] key is pressed outside the set range, it is not assured.
Set range: 1 - 13
At that time, when the [INTERRUPT] key is pressed, the data are not rewritten and the machine goes into the sub
code input standby mode.
When the [CA] key is pressed, the simulation is terminated without rewriting the data.
When any key input is made, it is displayed on the number of copies display. When the [START] key is pressed, the
set code data are acquired and stored in the EEPROM, and the machine goes into the sub code input standby
mode.
Set range: 1 - 99
(Change quantity 1
2msec/1Step)
At that time, when the [INTERRUPT] key is pressed, the data are not rewritten and the machine goes into the sub
code input standby mode.
When the [CA] key is pressed, the simulation is terminated without rewriting the data.
When the [START] key is pressed, the toner motor is driven for 30 sec while detecting the toner rotation. At this
moment, every time the rotation is detected, the [INTERRUPT] key indicator lights for 0.1 sec.
After completion of the process, the machine goes into the main code input standby mode.
When the [INTERRUPT] key is pressed, the machine goes into the main code input standby mode.
* With this simulation, the toner rotation sensor is sampled at intervals of 0.1 sec.
*
Trouble to write into the EEPROM such as H trouble is canceled and hardware reset is performed.
*
U2 trouble is canceled and hardware reset is performed.
When the [START] key is pressed, the maintenance count value is cleared and "000000" is displayed. (Alternate
display of "000" and "000")
When the [INTERRUPT] key is pressed, the machine goes into the main code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The current set maintenance cycle code is displayed (initial display), and the set data are stored.
Code
0
1
2
3
4
5
6
When the [INTERRUPT] key is pressed, the machine goes into the main code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The current set maintenance cycle code is displayed (initial display), and the set data are stored.
Code
0
1
2
When the [INTERRUPT] key is pressed, the machine goes into the main code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The maintenance counter value is displayed. (Three digits are displayed alternatively.)
When the [INTERRUPT] key is pressed, the machine goes into the main code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The copy quantity corresponding to the code that is set with SIM21-01 is displayed.
(For example: 50,000 sheets)
When the [INTERRUPT] key is pressed, the machine goes into the main code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The LED of the latest jam position is lighted. Every time when the [PRESET RATIO selector] keys is pressed, the
jam memory data is acquired sequentially from the latest. The jam position is judged by the acquired data and the
corresponding LED is lighted. The 7-seg display indicates the jam number. At that time, "A" is displayed on the
upper first digit. When the last one is displayed, the latest one will be displayed again. Max. 30 jams from the latest
are stored. When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode. When
the [CA] key is pressed, the simulation is terminated.
The jam total counter value is displayed. (Three digits are displayed alternatively.)
When the [INTERRUPT] key is pressed, the machine goes into the main code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The total counter value is displayed. (Three digits are displayed alternatively.)
When the [INTERRUPT] key is pressed, the machine goes into the main code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
AR-6020V SIMULATIONS 6-7
Details of operation
Default: 4
Default: 15
Setting
5,000 sheets
7,500 sheets
10,000 sheets
25,000 sheets
50,000 sheets
75,000 sheets (Default)
Free (999,999 sheets)
Setting
5,000 sheets (Default)
10,000 sheets
Free (999,999 sheets)