Sharp AR-6020V Service Manual page 47

Digital multifunctional system
Table of Contents

Advertisement

Main
Sub
Contents
code
code
06
Developing counter display
Mini maintenance preset display (Valid
07
only when the destination is set to
Japan AB series)
08
RSPF counter display
09
Paper feed counter display
10
Developer counter display
14
P-ROM version display
15
Trouble memory display
Duplex print counter display
16
22
(Duplex model only)
17
Copy counter display
18
Printer counter display
19
Scanner mode counter display
21
Scanner counter display
RSPF jam counter display
22
(Only when the RSPF is installed)
50
Developer rotation time display
51
Drum rotation time display
52
Toner rotation time display
The developing counter data is acquired and displayed. (Three digits are displayed alternatively.)
When the [INTERRUPT] key is pressed, the machine goes into the main code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The mini maintenance cycle data is acquired and displayed.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The RSPF counter value is displayed. (Three digits are displayed alternatively.)
The counter value of the selected paper feed section is acquired from each variable, the data is displayed on the
number of copies display according to the regulations. When this simulation is executed, the value of the 1st paper
tray is displayed first. Press the [TRAY SETTING] key to select the tray. When the [INTERRUPT] key is pressed,
the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The developer counter value is displayed. (Three digits are displayed alternatively.)
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The P-ROM version is displayed on the number of copies display The main code and the sub code are alternatively
displayed by 2 digits. The display interval is same as that of the counter display. By pressing the [AUTO/TEXT/
PHOTO] key, the display of the version is changed.
LED
TEXT indicator
PHOTO indicator
*1: Only when the NNB is installed.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The trouble codes are acquired from the trouble memory data.
Every time when the magnification ratio display is pressed, the main code of the trouble is displayed on the 1st ~
2nd digit.
*
The latest 20 troubles are stored in the memory.
The 3rd digit indicates the trouble history code, "A" ~ "J" (meaning of 1 ~ 10).
After "J" is displayed, "A" ~ "J" blinks. (Meaning of 11 ~ 20)
After "J" blinks (meaning of 20), "A" ~ "J" is lighted. (Returns to 1.)
When the [START] key is pressed, the sub code is displayed.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
*
Note that when the history code blinks, the trouble code and the sub code do not blink.
Data is acquired from the duplex print counter variable, and is displayed.
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The copy counter value is displayed. When the [INTERRUPT] key is pressed, the machine goes into the sub code
input standby mode. When the [CA] key is pressed, the simulation is terminated.
The printer counter value is displayed. When the [INTERRUPT] key is pressed, the machine goes into the sub code
input standby mode. When the [CA] key is pressed, the simulation is terminated.
The scanner mode counter value is displayed. When the [INTERRUPT] key is pressed, the machine goes into the
sub code input standby mode. When the [CA] key is pressed, the simulation is terminated.
The scanner counter value is displayed. When the [INTERRUPT] key is pressed, the machine goes into the sub
code input standby mode. When the [CA] key is pressed, the simulation is terminated.
The RSPF jam counter value is displayed. When the [INTERRUPT] key is pressed, the machine goes into the sub
code input standby mode. When the [CA] key is pressed, the simulation is terminated.
The developer counter and rotation distance and rotation number is displayed. (Three digits are displayed
alternatively.) By pressing the [AUTO/TEXT/PHOTO] key, the display of the version is changed.
LED
AUTO indicator
TEXT indicator
PHOTO indicator
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The drum counter and rotation distance and rotation number is displayed. (Three digits are displayed alternatively.)
By pressing the [AUTO/TEXT/PHOTO] key, the display of the version is changed.
LED
AUTO indicator
TEXT indicator
PHOTO indicator
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
The toner counter and the rotation number is displayed. (Three digits are displayed alternatively.) By pressing the
[AUTO/TEXT/PHOTO] key, the display of the version is changed.
LED
AUTO indicator
TEXT indicator
When the [INTERRUPT] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
AR-6020V SIMULATIONS 6-8
Details of operation
Displayed version
Machine program
NNB Program *1
Displayed version
Developer counter
Rotation distance
Rotation number
Displayed version
Drum counter
Rotation distance
Rotation number
Displayed version
Toner counter
Rotation number