Sharp AR-6020V Service Manual page 53

Digital multifunctional system
Table of Contents

Advertisement

: '19/Oct.
1
Main
Sub
code
code
1
<26/31 CPM>
43
01
Fusing temperature setting 1
Contents
<Fusing temperature setting 1>
With the simulation executed, the current set values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry..
Display
lamp
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
Contents
Ready standby TH_UM set value
Ready standby TH_US set value
Black-White plain paper TH_UM set value
Black-White plain paper TH_US set value
Fusing motor front rotation start TH-UM set value
Fusing motor front rotation end time
Warm-up complete time
Thin paper TH_UM set value
Thin paper TH_US set value
Heavy paper TH_UM set value
Heavy paper TH_US set value
Label paper TH_UM set value
Label paper TH_US set value
OHP TH_UM set value
OHP TH_US set value
Envelop TH_UM set value
Envelop TH_US set value
Preheating TH_UM set value
Preheating TH_US set value
TH_UH set value when recovering from preheating
TH_UM set value when Warm-Up at 120 degrees or below
TH_US set value when Warm-Up at 120 degrees or below
O, P valid time (Timer from Ready state)
TH_UM set value when Warm-Up at 120 degree C or
above
TH_US set value when Warm-Up at 120 degree C or above
R, S valid time (Timer from Ready state)
FM front rotation start TH_UM when Warm-Up at alpha
degree or above
Warm-Up completion time when Warm-Up at alpha degree
or above
Job approval TH_UM temperature (1) when Warm-Up at
alpha degree or above
Threshold alpha applying U -W
Job approval TH_UM temperature (1) when Warm-Up at
alpha degree or less
Rear rotation time at the job completion time
Job approval TH_UM temperature (2) when Warm-Up at
alpha degree or above
Job approval TH_UM temperature (2) when Warm-Up at
alpha degree or less
AR-6020V SIMULATIONS 6-14
Details of operation
Setting Display
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Setup
Reference
range
O
70 - 220
A
O
70 - 220
B
O
70 - 220
C
O
70 - 220
D
O
0 - 200
E
O
0 - 60
F
O
0 - 20
G
O
70 - 220
H
O
70 - 220
I
O
70 - 220
J
O
70 - 220
K
O
70 - 220
L
O
70 - 220
M
O
70 - 220
N
O
70 - 220
O
O
70 - 220
P
O
70 - 220
Q
O
70 - 220
R
O
70 - 220
S
O
70 - 220
T
O
70 - 220
U
O
70 - 220
V
O
0 - 255
W
O
70 - 220
X
O
70 - 220
Y
O
0 - 255
Z
O
0 - 220
AA
O
0 - 60
AB
O
30 - 220
AC
O
1 - 119
AD
O
70 - 220
AE
O
0 - 60
AF
O
70 - 220
AG
O
70 - 220
AH

Hide quick links: